Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- General
- Safety
- Limits of operation and use
- Risk from electrocution
- Personnel requirements - Qualifications
- Transport, storage and packaging
- Storage
- Technical data
- Construction and function
- Wear parts list
- Installation and wiring
- Requirements governing the installation site
- Minimum clearances
- Installation
- Installation of basic unit
- Installation of casing
- Installing the sheet steel accessories
- Connection to the pipe network
- Sealing the pipework to the valve condensation tray
- Overview of valve kits
- Connection of 2-way valve kit
- Connection of 3-way valve kit
- Connection of differential pressure-dependent valve kit
- Condensation connection
- Electrical wiring
- Electromechanical control, Venkon AC
- Cabling, Venkon AC (*A00M), control by room thermostat type 148916
- Cabling, Venkon AC (*A00M), control by room thermostat type 148916, with condensation monitor
- Cabling, Venkon AC (*A00M), control by room thermostat type 148915/148918/148917
- Cabling, Venkon AC (*A00M), control by room thermostat type 148915/148918/148917, with con
- Electromechanical control, Venkon EC
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30155
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30155, with condensation monitor
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30256
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30256, with condensation monitor
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller Type 148941/148942
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller Type 148941/148942, with condens
- KaControl (*C1)
- Connection (*C1)
- Cabling, Venkon EC, KaControl (*C1*), control by KaController
- Cabling, Venkon EC, KaControl (*C1*), control by in situ 0-10 V DC signal
- Pre-commissioning checks
- Operation
- Operation of the KaController
- Maintenance
- Maintenance work
- Cleaning the main condensation tray
- Cleaning the valve condensation tray
- Clean the inside of the unit
- Faults
- KaControl faults
- List of KaControl parameters
- KaController parameter list
- Certificates
- Table
|
VenkonAssembly, installation and operating instructions457.3 Electromechanical control, Venkon EC7.3.1 Connection (*00M or 01M), Venkon ECFig. 30: Remove junction box from the Velcro stripThe junction box for electromechanical control (AC and EC) aswell as the junction box for the condensation monitor can beelectrically installed separately from the side panel of the ba-sic unit by Velcro fitting. Simply remove the plastic lid to openthe junction box.Description of wiringFactory-fitted actuators are wired to the terminal. If no valve actuators are factory-fitted, support terminals are availablefor on-site valve actuators.The speed of EC fans used is continuously variably controlled by a 0 – 10 V DC signal. The”intelligent” motor electronicsdetects any possible motor fault and automatically switch the fan off.Control version *01M: A potential-free “motor fault signal” contact is also available for external evaluation.Power supplyCondensation alarmmessageFuseJunction box for condensation monitor Junction box for Venkon EC electromechanicalPower supplyValve actuator(s) Speed and,motor faultsignal, if requiredFig. 31: Junction boxes Venkon EC