- General
- Safety
- Limits of operation and use
- Risk from electrocution
- Personnel requirements - Qualifications
- Transport, storage and packaging
- Storage
- Technical data
- Construction and function
- Wear parts list
- Installation and wiring
- Requirements governing the installation site
- Minimum clearances
- Installation
- Installation of basic unit
- Installation of casing
- Installing the sheet steel accessories
- Connection to the pipe network
- Sealing the pipework to the valve condensation tray
- Overview of valve kits
- Connection of 2-way valve kit
- Connection of 3-way valve kit
- Connection of differential pressure-dependent valve kit
- Condensation connection
- Electrical wiring
- Electromechanical control, Venkon AC
- Cabling, Venkon AC (*A00M), control by room thermostat type 148916
- Cabling, Venkon AC (*A00M), control by room thermostat type 148916, with condensation monitor
- Cabling, Venkon AC (*A00M), control by room thermostat type 148915/148918/148917
- Cabling, Venkon AC (*A00M), control by room thermostat type 148915/148918/148917, with con
- Electromechanical control, Venkon EC
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30155
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30155, with condensation monitor
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30256
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30256, with condensation monitor
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller Type 148941/148942
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller Type 148941/148942, with condens
- KaControl (*C1)
- Connection (*C1)
- Cabling, Venkon EC, KaControl (*C1*), control by KaController
- Cabling, Venkon EC, KaControl (*C1*), control by in situ 0-10 V DC signal
- Pre-commissioning checks
- Operation
- Operation of the KaController
- Maintenance
- Maintenance work
- Cleaning the main condensation tray
- Cleaning the valve condensation tray
- Clean the inside of the unit
- Faults
- KaControl faults
- List of KaControl parameters
- KaController parameter list
- Certificates
- Table
|
VenkonAssembly, installation and operating instructions79Parameter Function Standard Min. Max. Unit Venkon 2P118 On delay time 0 0 255 sec 0P119 Off delay time 0 0 255 sec 0P120 reserved - - - - -P121 reserved - - - - -P122 Relative fan speed increase via contact 2 0 5 - 2P123 Maximum valve running time 150 0 255 sec 150P124 Minimum P + I output variation for valve motion (0 to 10) 5 0 100 % 5P125 reserved - - - - -P126 Weeks of operation 0 0 255 week 0P127 Info weeks of operation reached (filter message) 0 52 255 week 0P128 Reset weeks of operation 0 0 1 - 0P129 Fan speed limiter activation in certain operating modes 0 0 1 - 0P130 Absolute fan speed increase via contact 2 0 5 - 2P131 External ventilation, delay time 0 0 255 min 0P132 Operating level, master password 22 0 255 - 22P133 Hysteresis for outside temperature to switch between heat-ing/fan mode 0 0 255 K/10 0P134 Threshold for outside temperature to switch between heat-ing/fan mode 0 0 50 °C 0P135 Enable virtual sensor 0 0 1 - 0P136 Enable external ventilation 0 0 2 - 0Tab. 15: Key parameters, standard revision 1.024 from 01.05.201812.2 KaController parameter listPara-meterFunction Standard Min. Max. Unit Commentt001 Serial address 1 0 207 - Address in Mod-bus networkt002Baud rate0 = Baud rate 48001 = Baud rate 96002 = Baud rate 192002 0 2 -t003Background lighting function0 = Slow fade in, fast fade out1 = Slow fade in, slow fade out2 = Fast fade in, fast fade out0 0 2 -t004 Strong background lighting 4 0 5 -t005 Sensor calibration of KaController sensor 0 60 60 °Ct006 LCD display contrast 15 0 15 -t007BEEP setting0 = BEEP ON1 = BEEP OFF0 0 1 -t008 Password for KaController Parameter menu 11 0 999 -t009 Minimum settable setpoint temperature 8 0 20 °Ct010 Maximum settable setpoint temperature 35 10 40 °C