Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- General
- Safety
- Limits of operation and use
- Risk from electrocution
- Personnel requirements - Qualifications
- Transport, storage and packaging
- Storage
- Technical data
- Construction and function
- Wear parts list
- Installation and wiring
- Requirements governing the installation site
- Minimum clearances
- Installation
- Installation of basic unit
- Installation of casing
- Installing the sheet steel accessories
- Connection to the pipe network
- Sealing the pipework to the valve condensation tray
- Overview of valve kits
- Connection of 2-way valve kit
- Connection of 3-way valve kit
- Connection of differential pressure-dependent valve kit
- Condensation connection
- Electrical wiring
- Electromechanical control, Venkon AC
- Cabling, Venkon AC (*A00M), control by room thermostat type 148916
- Cabling, Venkon AC (*A00M), control by room thermostat type 148916, with condensation monitor
- Cabling, Venkon AC (*A00M), control by room thermostat type 148915/148918/148917
- Cabling, Venkon AC (*A00M), control by room thermostat type 148915/148918/148917, with con
- Electromechanical control, Venkon EC
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30155
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30155, with condensation monitor
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30256
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30256, with condensation monitor
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller Type 148941/148942
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller Type 148941/148942, with condens
- KaControl (*C1)
- Connection (*C1)
- Cabling, Venkon EC, KaControl (*C1*), control by KaController
- Cabling, Venkon EC, KaControl (*C1*), control by in situ 0-10 V DC signal
- Pre-commissioning checks
- Operation
- Operation of the KaController
- Maintenance
- Maintenance work
- Cleaning the main condensation tray
- Cleaning the valve condensation tray
- Clean the inside of the unit
- Faults
- KaControl faults
- List of KaControl parameters
- KaController parameter list
- Certificates
- Table
|
VenkonAssembly, installation and operating instructions629 Operation9.1 Operation of electromechanical controlControls, Venkon ACFig. 36: Room thermostat, type 196000148915/196000148918/ 196000148917Room thermostat, type 196000148915/ 196000148918/196000148917Electronic room thermostat with 3-stage switch for 2-pipe applications, surface-mounted wall mounting on a flush-mounted box in visually unobtrusive design.Parallel operation of 2 units is possible.type 148915 (heating only)type 148918 (cooling only)type 148917 (heating/cooling changeover)Fig. 37: Room thermostat type 196000148916Room thermostat type 196000148916Electronic room thermostat with 3-stage switch for 2- and 4-pipe applica-tions, surface-mounted wall mounting on a flush-mounted box in visuallyunobtrusive designOption for external room sensorControl input for heating/cooling changeover with 2-pipe systemsDigital input can either be set to Comfort/ECO or ON/OFF switchoverParallel operation of 2 units is possible