Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- General
- Safety
- Limits of operation and use
- Risk from electrocution
- Personnel requirements - Qualifications
- Transport, storage and packaging
- Storage
- Technical data
- Construction and function
- Wear parts list
- Installation and wiring
- Requirements governing the installation site
- Minimum clearances
- Installation
- Installation of basic unit
- Installation of casing
- Installing the sheet steel accessories
- Connection to the pipe network
- Sealing the pipework to the valve condensation tray
- Overview of valve kits
- Connection of 2-way valve kit
- Connection of 3-way valve kit
- Connection of differential pressure-dependent valve kit
- Condensation connection
- Electrical wiring
- Electromechanical control, Venkon AC
- Cabling, Venkon AC (*A00M), control by room thermostat type 148916
- Cabling, Venkon AC (*A00M), control by room thermostat type 148916, with condensation monitor
- Cabling, Venkon AC (*A00M), control by room thermostat type 148915/148918/148917
- Cabling, Venkon AC (*A00M), control by room thermostat type 148915/148918/148917, with con
- Electromechanical control, Venkon EC
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30155
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30155, with condensation monitor
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30256
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30256, with condensation monitor
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller Type 148941/148942
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller Type 148941/148942, with condens
- KaControl (*C1)
- Connection (*C1)
- Cabling, Venkon EC, KaControl (*C1*), control by KaController
- Cabling, Venkon EC, KaControl (*C1*), control by in situ 0-10 V DC signal
- Pre-commissioning checks
- Operation
- Operation of the KaController
- Maintenance
- Maintenance work
- Cleaning the main condensation tray
- Cleaning the valve condensation tray
- Clean the inside of the unit
- Faults
- KaControl faults
- List of KaControl parameters
- KaController parameter list
- Certificates
- Table
|
VenkonAssembly, installation and operating instructions477.3.2 Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30155gn/ge1211gn/ge311222423gn/ge123121241212121 2 3 4 5 6 7 8 9 10 11 12 13 14N N N L H K AI GND AO GND UI GND DI GND3412COMNO 1 2121212COMNO2* W72* W8W4W6W32*2*552*W5VK UC GNDL N PE 1 2 VH 5 6 VK UC GNDL N PE 1 2 VH 5 64W23W1N PEL12gn/geMains 230 V/50HzVenkon ECelectromechanical (*00M or *01M)Climate controller type30155Fuse by others.Refer to "Electricaldata” informationtable.Mains power 230V ACUnit no. 1 Unit no. 23 of 5 fan stagesValve drive(s) 230 V ACOpen/ClosedFan junction box Mains power 230 V ACFan junction boxValve drive(s) 230 V ACOpen/ClosedJumperJumperContact e.g. window Contacte.g. heating/cooling Room sensor- Options -For more information, see the instructions for the climatecontroller- Option -Fault SpeedFanVenkon ECelectromechanical (*00M or *01M)Evaluationon siteFanRefer to "Electrical data”information table!- Option -Fault SpeedEvaluationon site