Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- General
- Safety
- Limits of operation and use
- Risk from electrocution
- Personnel requirements - Qualifications
- Transport, storage and packaging
- Storage
- Technical data
- Construction and function
- Wear parts list
- Installation and wiring
- Requirements governing the installation site
- Minimum clearances
- Installation
- Installation of basic unit
- Installation of casing
- Installing the sheet steel accessories
- Connection to the pipe network
- Sealing the pipework to the valve condensation tray
- Overview of valve kits
- Connection of 2-way valve kit
- Connection of 3-way valve kit
- Connection of differential pressure-dependent valve kit
- Condensation connection
- Electrical wiring
- Electromechanical control, Venkon AC
- Cabling, Venkon AC (*A00M), control by room thermostat type 148916
- Cabling, Venkon AC (*A00M), control by room thermostat type 148916, with condensation monitor
- Cabling, Venkon AC (*A00M), control by room thermostat type 148915/148918/148917
- Cabling, Venkon AC (*A00M), control by room thermostat type 148915/148918/148917, with con
- Electromechanical control, Venkon EC
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30155
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30155, with condensation monitor
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30256
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30256, with condensation monitor
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller Type 148941/148942
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller Type 148941/148942, with condens
- KaControl (*C1)
- Connection (*C1)
- Cabling, Venkon EC, KaControl (*C1*), control by KaController
- Cabling, Venkon EC, KaControl (*C1*), control by in situ 0-10 V DC signal
- Pre-commissioning checks
- Operation
- Operation of the KaController
- Maintenance
- Maintenance work
- Cleaning the main condensation tray
- Cleaning the valve condensation tray
- Clean the inside of the unit
- Faults
- KaControl faults
- List of KaControl parameters
- KaController parameter list
- Certificates
- Table
|
VenkonAssembly, installation and operating instructions427.2.3 Cabling, Venkon AC (*A00M), control by room thermostat type 148916, with condensation monitorN PEL12gn/geNC COML N PE NOPE N S1 S2 S3 S4 S5 TK TK VK1 2 VHgn/ge234563412gn/ge1gn/ge123456gn/ge12gn/ge123456734NC COML N PE NOPE N S1 S2 S3 S4 S5 TK TK VK1 2 VHgn/ge234563412gn/ge1gn/ge123456gn/ge1234gn/ge12345671 2 3 4 5 6 7 8 9 10 11 12 13 14LVVmaxVmedVminn.c.LLNNCH GND15 16 17 18 19GND DIGND DIAI n.c. n.c.12345671212122* W92* W10W82*1234567gn/ge123W1W27W35W78W57W658W4COMNO 1 2121212COMNOMains 230 V/50Hz Venkon AC electromechanical *00M Venkon AC electromechanical *00MJunction box on siteRoom thermostattype 148916Fuse by others.Refer to "Electricaldata” informationtable.Mains power 230V ACUnit no. 1 Unit no. 23 of 5 fan stagesValve drive(s) 230 V ACOpen/ClosedFan junction box3 of 5 fan stagesFan junction boxValve drive(s) 230 V ACOpen/ClosedJumperJumperContact e.g. window Contacte.g. heating/cooling Room sensor- Options -For more information, see the instructions for the roomthermostatMains power230 V ACCondensation alarm Condensation alarmMains power230 V ACJunction box on siteJunction box for condensationmonitorJunction box for condensationmonitor
PreviousNext |