Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- General
- Safety
- Limits of operation and use
- Risk from electrocution
- Personnel requirements - Qualifications
- Transport, storage and packaging
- Storage
- Technical data
- Construction and function
- Wear parts list
- Installation and wiring
- Requirements governing the installation site
- Minimum clearances
- Installation
- Installation of basic unit
- Installation of casing
- Installing the sheet steel accessories
- Connection to the pipe network
- Sealing the pipework to the valve condensation tray
- Overview of valve kits
- Connection of 2-way valve kit
- Connection of 3-way valve kit
- Connection of differential pressure-dependent valve kit
- Condensation connection
- Electrical wiring
- Electromechanical control, Venkon AC
- Cabling, Venkon AC (*A00M), control by room thermostat type 148916
- Cabling, Venkon AC (*A00M), control by room thermostat type 148916, with condensation monitor
- Cabling, Venkon AC (*A00M), control by room thermostat type 148915/148918/148917
- Cabling, Venkon AC (*A00M), control by room thermostat type 148915/148918/148917, with con
- Electromechanical control, Venkon EC
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30155
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30155, with condensation monitor
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30256
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30256, with condensation monitor
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller Type 148941/148942
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller Type 148941/148942, with condens
- KaControl (*C1)
- Connection (*C1)
- Cabling, Venkon EC, KaControl (*C1*), control by KaController
- Cabling, Venkon EC, KaControl (*C1*), control by in situ 0-10 V DC signal
- Pre-commissioning checks
- Operation
- Operation of the KaController
- Maintenance
- Maintenance work
- Cleaning the main condensation tray
- Cleaning the valve condensation tray
- Clean the inside of the unit
- Faults
- KaControl faults
- List of KaControl parameters
- KaController parameter list
- Certificates
- Table
|
VenkonAssembly, installation and operating instructions7612 List of KaControl parameters12.1 Venkon parameter listParameter Function Standard Min. Max. Unit Venkon 2P000 Software version 24 0 255 - 24P001 Base setpoint for setpoint entry ± 3K 22 8 32 °C 22P002 Switching on / off hysteresis for valves 3 0 255 K/10 1P003 Neutral zone in a 4-pipe system (only in automatic mode) 3 0 255 K/10 3P004 Cooling without fan assistance (natural convection) 0 0 255 K/10 0P005 Heating without fan assistance (natural convection) 5 0 255 K/10 3P006 Fan On/Off hysteresis (only in ventilation mode) 5 0 255 K/10 5P007 P-band for heating 20 0 100 K/10 17P008 P-band for cooling 20 0 100 K/10 20P009 Offset to the base setpoint for setpoint input ± 3K 3 0 10 C 3P010 Clip-on sensor: Limit temperature to activate fan stages 1and 2 in heating mode 26 0 255 °C 26P011 Clip-on sensor: Limit temperature to activate fan stages 3and 4 in heating mode 28 0 255 °C 28P012 Clip-on sensor: Limit temperature to activate fan stage 5 inheating mode 30 0 255 °C 30P013 Clip-on sensor: Hysteresis for limit temperaturesP010, P011, P012, P014 10 0 255 K/10 10P014 Clip-on sensor: limit value temperature to activate the fanstages in cooling mode 18 0 255 °C 18P015 Function of input AI1 0 0 19 - 0P016 Function of input AI2 0 0 19 - 0P017 Function of input AI3 0 0 9 - 0P018 Raise temperature of cooling setpoint in Eco mode 30 0 255 K/10 30P019 Lower temperature of heating setpoint in Eco mode 30 0 255 K/10 30P020 ADC limit coefficient 6 0 15 - 6P021 ADC average coefficient 6 0 15 - 6P022 Activation/disabling of sun symbol in Comfort mode 0 0 1 - 0P023 Difference for compensation during cooling 0 -99 127 K/10 0P024 Coefficient for compensation during heating 0 -20 20 1/10 0P025 Difference for compensation during heating 0 -99 127 K/10 0P026 Coefficient for compensation during heating 0 -20 20 1/10 0P027 Fan setting: maximum run-time for manual fan mode 0 0 255 min 0P028 Flushing function: fan stage during the flushing function 2 1 5 - 2P029 Activation of continuous fan mode 0 0 1 - 0P030 Ventilate temperature activation 12 0 255 °C 12P031 Ventilation interval 27 0 255 °C 27P032 Flushing function: maximum idle time of fan 15 0 255 min 15P033 Flushing function: duration of flushing function 120 0 255 s 120P034 Flushing function: activation in operating modes 0 0 3 - 02 Parameter key Venkon SAP no. 9000816, dated 1.02.2018
PreviousNext |