Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- General
- Safety
- Limits of operation and use
- Risk from electrocution
- Personnel requirements - Qualifications
- Transport, storage and packaging
- Storage
- Technical data
- Construction and function
- Wear parts list
- Installation and wiring
- Requirements governing the installation site
- Minimum clearances
- Installation
- Installation of basic unit
- Installation of casing
- Installing the sheet steel accessories
- Connection to the pipe network
- Sealing the pipework to the valve condensation tray
- Overview of valve kits
- Connection of 2-way valve kit
- Connection of 3-way valve kit
- Connection of differential pressure-dependent valve kit
- Condensation connection
- Electrical wiring
- Electromechanical control, Venkon AC
- Cabling, Venkon AC (*A00M), control by room thermostat type 148916
- Cabling, Venkon AC (*A00M), control by room thermostat type 148916, with condensation monitor
- Cabling, Venkon AC (*A00M), control by room thermostat type 148915/148918/148917
- Cabling, Venkon AC (*A00M), control by room thermostat type 148915/148918/148917, with con
- Electromechanical control, Venkon EC
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30155
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30155, with condensation monitor
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30256
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30256, with condensation monitor
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller Type 148941/148942
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller Type 148941/148942, with condens
- KaControl (*C1)
- Connection (*C1)
- Cabling, Venkon EC, KaControl (*C1*), control by KaController
- Cabling, Venkon EC, KaControl (*C1*), control by in situ 0-10 V DC signal
- Pre-commissioning checks
- Operation
- Operation of the KaController
- Maintenance
- Maintenance work
- Cleaning the main condensation tray
- Cleaning the valve condensation tray
- Clean the inside of the unit
- Faults
- KaControl faults
- List of KaControl parameters
- KaController parameter list
- Certificates
- Table
|
VenkonAssembly, installation and operating instructions487.3.3 Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30155, with condensation monitorgn/ge12113gn/ge4112212gn/ge3244312gn/ge123gn/ge1212gn/ge341gn/ge2312124323 5 3 53W1 W2 W3 W5W42*W8VK UC GNDL N PE 1 2 VH 5 6 NC COML N PE NO VK UC GNDL N PE 1 2 VH 5 6 NC COML N PE NON PEL12gn/ge1241212121 2 3 4 5 6 7 8 9 10 11 12 13 14N N N L H K AI GND AO GND UI GND DI GND312COMNO 1 2121212COMNO2* 2*2*2*5W10W11W7W9W6Mains 230 V/50HzVenkon ECelectromechanical (*00M or *01M)Climate controller type30155Fuse by others.Refer to "Electricaldata” informationtable.Mains power 230V ACUnit no. 1 Unit no. 2Valve drive(s) 230 V ACOpen/ClosedFan junction boxMains power 230 VACJunction box for condensationmonitorValve drive(s) 230 V ACOpen/ClosedJumperContact e.g. window Contacte.g. heating/cooling Room sensor- Options -For more information, see the instructions for the climatecontroller- Option -Fault SpeedFanVenkon ECelectromechanical (*00M or *01M)Evaluationon siteFanCondensation alarm- Option -Fault SpeedEvaluationon siteJunction box for condensationmonitorMains power 230 VACCondensation alarm230 V ACRefer to "Electricaldata” informationtable!230 V ACRefer to "Electricaldata” informationtable!