Electrical System142Service Manual – CS7000Current SensorsAmperage Measured Voltage Output120 A 4.5v60 A 3.5v45 A 3.25v30 A 3.0v15 A 2.75v0 A 2.5v-60 A 1.5v-120 A 0.5vInput/Output TableConn. Pin Wire Desig. Description ID Signal Nominal Value Black voltmeter leadon:J2 1 091 ORN/YELOutput Left Front Turn Lamp LT7 12V OFF / 0V ON B-(Ground)J2 2 094 ORN/BLUOutput Left Rear Tail Lamp LT9 12V OFF / 0V ON B-(Ground)J2 3 098 YEL/REDOutput Right Front Turn Lamp LT4 12V OFF / 0V ON B-(Ground)J2 4 101 YEL/GRNOutput Right Rear Stop/TurnLampLT11 12V OFF / 0V ON B-(Ground)J2 5 107 TAN/BLKOutput Tail Lamps LT5 andLT612V OFF / 0V ON B-(Ground)J2 6 064 BLK/YELOutput Dust Control MotorContactorK6 Grounds toenergize36V OFF / 0V ON B-(Ground)J2 7 119 BRN/WHTOutput Detergent Pump M17 PWM SIGNAL(ReversingPolarity)0-12V J2-19J2 8 080 WHT/GRNOutput Squeegee ActuatorMotorM12 ReversingPolarityBattery 30.5- 38VEngine ON 37-40.5VJ2-9J2 9 078 BLU/BRNOutput Squeegee ActuatorMotorM12 ReversingPolarityBattery 30.5- 38VEngine ON 37-40.5VJ2-8J2 10 132 RED/GRNOutput Scrub Deck ActuatorMotorM11 ReversingPolarityBattery 30.5- 38VEngine ON 37-40.5VJ2-11J2 11 135 YEL/GRAOutput Scrub Deck ActuatorMotorM11 ReversingPolarityBattery 30.5- 38VEngine ON 37-40.5VJ2-10J2 12 162 BLK Ground Supply Battery Negative Battery 30.5- 38VEngine ON 37-40.5VB+J2 13 057 VIO PowerSupplyVACC 1 Power supplyfrom AuxContactorBattery 30.5- 38VEngine ON 37-40.5VB-(Ground)J2 14 051 BLK/ORNOutput Auxiliary Contactor K9 Grounds toenergize36V OFF / 0V ON B-(Ground)J2 15 163 BRN/BLKOutput Side Broom MotorContactorK8 Grounds toenergize36V OFF / 0V ON B-(Ground)J2 16 063 GRN/GRAOutput Main Broom MotorContactorK4 Grounds toenergize36V OFF / 0V ON B-(Ground)J2 17 045 BLU Output Vacuum MotorContactorK5 Grounds toenergize36V OFF / 0V ON B-(Ground)J2 18 150 BLK/REDOutput Shaker MotorgroundM14 PWM SIGNAL(half secondcycles)Battery 30.5- 38VEngine ON 37-40.5VB-(Ground)J2 19 116 WHT/YELOutput Detergent Pump M17 PWM SIGNAL(ReversingPolarity)0-12V J2-7