Control System53Service Manual – CS7000Fault Code Table (Main machine controller)Fault # Description Setting Conditions ConsequencesNone Power Distribution Fault If the voltage of the 36v batterypack falls too low, the LCD willdisplay this message. You needto charge the 36v battery pack.00 Auxiliary Contactor (K9) WindingCircuit OverloadShort circuit or > 4 Amps01 12 Volt Alternator is not charging Battery voltage is less than 10volts with the engine running02 Not used03 Not used04 Excessive Engine Temperature* Engine Temperature switchclosed with the engine running.Shut down engine05 Low Engine Oil Pressure* Loss of engine run signal (Oilpressure switch open) with thekey switch still on.Shut down engine06 Glow Plug Relay Overload07 42 Volt Alternator is not charging < 37 volts for > 30 Seconds.08 Throttle 1 circuit overload Current Overload09 Throttle 2 circuit overload Current OverloadFault # Description Setting Conditions Consequences10 Start Command circuit overload > 18 Amps11 Ignition On circuit overload > 18 AmpsFault # Description Setting Conditions Consequences12 VACC1 circuit breaker tripped Aux Contactor energized withno voltage at J2-13 VACC113 VACC2 circuit breaker tripped Aux Contactor energized withno voltage at J3-26 VACC2