116 Chapter 10 RAID operations10 Locate SCSI controllers → LSI Adapter in the RAIDUP directory.Double click on it, then select Driver.Result: You are asked to choose the Upgrade Driver.11 Point to the c:\raidup\Win2k3 folder.12 The system asks you to reboot.Result: The system reboots to Windows 2003.13 Check the driver, firmware and Power Console configuration.a. Open the MegaRAID Power Console from the Start → Programsmenu.b. Select Help About from the menu and verify the MegaRAIDPower Console version is 5.00i.c. Select Adapter → Properties and verify the firmware version is1L37 and the board type is LSI320-2.d. Exit the Power Console.14 Right click on C:\WINNT\SYSTEM32\DRIVERS\mraid3xx.sys andselect Properties → Version. Verify the Driver version is 6.45.—End—Configuring the RAID controller after a hardware changeThe RAID card’s configuration is stored on both the card and on the harddrive, so typically you are not required to reconfigure RAID unless you aremaking a change to the RAID system (for example, if you replace the harddrives with higher-capacity hard drives).CAUTIONRisk of data lossThis procedure requires that the logical drive be initialized. Whenyou initialize the logical drive, all data on the hard drives is erased.Do not perform this procedure unless you are replacing thehard drives, or you are rebuilding the CallPilot system (that is,reinstalling the Windows operating system and CallPilot software).WARNINGNortel strongly recommends that you not perform low levelformatting. Performing low level formatting results in the drivesbecoming unusable.Nortel CallPilot1002rp Server Maintenance and DiagnosticsNN44200-701 01.02 Standard5.0 4 April 2007Copyright © 2007, Nortel Networks Nortel Networks Confidential.