96 InstallationProcedure 2Wall-mounting the WLAN IP Telephony Manager 2245Step Action1 Use a 18-inch drill bit to drill four pilot holes, on 1.84 by 12.1 inchcenters (approximately equivalent to 1-1316 inch by 12-18 inch).2 Insert the #8 x 34-inch screws in the pilot holes and tighten, leavinga 18 to 14-inch gap from the wall.3 Slide the WLAN IP Telephony Manager 2245 over the screws untilthe WLAN IP Telephony Manager 2245 drops into place in thekeyhole openings of the flange.4 Tighten screws fully.—End—Rack-mountThe rack-mount kit is designed for mounting the WLAN IP TelephonyManager 2245 in a standard 19-inch rack and contains the followingequipment:• Mounting plates—two for each WLAN IP Telephony Manager 2245 tobe mounted.• Screws—four rack-mount screws for each WLAN IP Telephony Manager2245 to be mounted.Follow the steps in Procedure 3 "Rack-mounting the WLAN IP TelephonyManager 2245" (page 96) to rack-mount the WLAN IP Telephony Manager2245.Procedure 3Rack-mounting the WLAN IP Telephony Manager 2245Step Action1 Remove the corner screws from the WLAN IP Telephony Manager2245.2 Screw the U-shaped end (round screw holes) of the two mountingplates to the WLAN IP Telephony Manager 2245.3 Screw the other end of the two mounting plates (oblong screw holes)to the rack.Nortel Communication Server 1000WLAN IP Telephony Installation and CommissioningNN43001-504 01.02 StandardRelease 5.0 15 June 2007Copyright © 2004-2007, Nortel Networks.