35Main Menu (continued)Sub menu Settings DescriptionCOLOR SPACE *5 SMPTE-CEBUITU-709 *6Sets the studio standard color space.POWER SAVEMODEOFFONSets the power save mode The backlight dims when no signal (NO SIGNAL) is inputfor 60 seconds or longer. Signal input or menu operationwill return the backlight to its normal brightness.CALIBRATION ▼ Connect Display Color Analyzer CA-210 and then performcalibration. This also allows you to restore the calibration data tothe factory preset setting values.(pages 35, 36, and 37)AREA SETTING NTSCNTSC (J)PALSelects the area of the unit.(→ “Selecting Area of Use” on page 8)The setting does not vary depending on the operation of SETUP•LOAD or POWER ON SETUP.The factory preset setting value varies depending on the area set in “AREA SETTING”.*5ITU-709 indicates the ITU-R BT.709 standard.*6CALIBRATION■The CALIBRATION function in this unit measures LCD panel characteristics from low to high brightnessvalues and internal monitor processing handles CALIBRATION.CALIBRATION does not rely on image quality settings since internal signals are used for a calibration.CALIBRATION in this unit is made at D65 color temperature and other color temperatures are resultscalculated automatically from this value.Equipment required for calibration■Konica Minolta CA-210•or CA-310 display coloranalyzerKonica Minolta CA-•PU12 or CA-PU15standard measurement probeA RS-232C cable (male to male, straight)•Connect the SERIAL terminal on this unit to the RS-232C terminal on the display color analyzer using astraight cable.(Continued on next page)SERIAL Terminal (9P)Analyzer Side (Straight) This unit SidePin number Signal Pin number Signal1 CD 1 N.C.2 RXD 2 TXD3 TXD 3 RXD4 DTR 4 DSR5 GND 5 GND6 DSR 6 DTR7 RTS 7 CTS8 CTS 8 RTS9 GND 9 N.C.