8-28.1 ALARM indicationThis is the explanation about wireless unit ALARM indication.ALARM indication means the below cautions and error according to the operating mode.In case of operating mode is “TEST”, it has another meanings not cautions or error. Please refer to<6.2 Test functions of main unit>.Reference: <6.2 Test functions of main unit> When operating mode is “SET”ALARM indication Meaning TroubleshootingCommand error whencommand not for wirelessunit is inputDelete this data by wireless unit.In case of operating mode is “SET”, wirecommunication can be used with onlysetting tool. In order to do normalcommunication, set to “RUN”.Light for a momentCommunication error withsetting toolRefer to dialog by setting tool.Blinking Cautions to show duringinitializing mode (MODEswitch No.9 is ON.)Set MODE switch No.9 OFF and turnpower on again.When slaveregistrationBlinkingError to indicate failure ofslave registrationRefer to <Chapter 4 Resister slave>about how to register slaveWhen initializing Cautions to show duringinitializing modeCheck with <5.9 Initialization>Blinking When operating mode is “RUN”ALARM indication Meaning TroubleshootingLight for a moment Communication error anddata are deletedRefer to <8.2 Troubleshooting>Error to show that slaveisn’t registered.Register slaveError to show that routingsetting is not set.Set routing settingLightingcontinuouslyWith 1:1 topology, MODEswitch No.1 is ON.When 1:1 topology, set MODE switchNo.1 to OFF.With I/O type,When outputingcommunication error(Lighting communicationerror LED)It can’t communicate by wirelesscommunication. Check power supply,communication setting, mounting place,radio wave conditions and so on of bothsides.※When operating mode is “RUN”, error contents can be read out by using setting tool.Note: When it lights for a moment, it keeps communication, however, when it lightscontinuously, it can’t communicate.Reference: <6.3.6 Read log> Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net