10-510.3.3 Connect to FP2 unit Connecting cable wiring diagramD-SUB 9-pin female D-SUB 9-pin malePin No. Signal name Pin No. Signal name1 - 1 FG2 RD 2 SD3 SD 3 RD4 - 4 RS5 SG 5 CS6 - 6 -7 RS 7 SG8 CS 8 -9 - 9 ER10.3.4 Connect to FP-X control unitIn order to connect wireless unit, attach communication cassette to FP-X control unit.Usable communication cassette (RS232C communication type)Name Model No.FP-X COM1 communication cassette (RS232C 1CH type) AFPX-COM1FP-X COM2 communication cassette (RS232C 2CH type) AFPX-COM2FP-X COM4 communication cassette (RS485 1CH/RS232C 1CHtype) AFPX-COM4 Connecting cable wiring diagramz AFPX-COM1D-SUB 9-pin femalePin No. Signal name Pin name3 SD SD2 RD RD7 RS RS8 CS CS5 SG SG(Terminals without print are no connection.)z AFPX-COM2D-SUB 9-pin femalePin No. Signal name Pin name3 SD S12 RD R17 RS S28 CS R25 SG SG(Terminals without print are no connection.)z AFPX-COM4D-SUB 9-pin femalePin No. Signal name Pin name3 SD +2 RD -7 RS SD8 CS RD5 SG SG(Terminals without print are no connection.)Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net