172 Human Readable TextSpecifies the human readable text settings of the following code symbols.• CODE128• EAN/UPC• GS1 DataBar, GS1 DataBar Limited, GS1 DataBar Expanded• GS1 Data Matrix• Composite codes1 627349510 11 128Description1 Relative X Position, Relative Y Position (except EAN/UPC code) :Specifies relative coordinate of X/Y position of Human Readable Text when the center of the code is defined as theorigin point.Setting Range -60.000 to +60.000 mm (LP-M500 / LP-Z130)*-45.000 to +45.000 mm (LP-S500)*2 Character Height, Character Width (except EAN/UPC code) :Specifies the character height / width of Human Readable Text.Setting Range 0.100 to 120.000 mm (LP-M500 / LP-Z130)*0.100 to 90.000 mm (LP-S500)*3 Character Interval (except EAN/UPC code) :Specifies the character interval of Human Readable Text.Setting Range 0.000 to 120.000 mm (LP-M500 / LP-Z130)*0.000 to 90.000 mm (LP-S500)*4 Line Feed (Only for 2D side of composite code / GS1 data matrix code) :When the code data of 2D code or 2D side of the composite code is set in the several strings, set whether thelinefeed is applied to the human readable text or not.Selects “ON” for marking Human Readable Text per 2D code data with line feed. If marking one character stringwithout line feed, select “OFF”.5 Line Interval :When “line feed” is set ON, specifies the line interval of Human Readable Text.Setting Range 0.000 to 120.000 mm (LP-M500 / LP-Z130)*0.000 to 90.000 mm (LP-S500)*6 Font :Select font type of Human Readable Text from the registered font.7 Bold Line Width :Specifies the line width of bold character.Setting Range 0.000 to 2.000 mm (LP-M500 / LP-S500 / LP-Z130)*ME-LPMSZ-OP-7