197Equidistant MarkingMarking is repeated every time the line moves with the interval set in equidistant marking.Equidistant marking is performed while the marking trigger is turned to ON.Reference• Equidistant marking on the flying object cannot be used in combination with rank marking, external offset, and serialdata marking function.When the encoder is not used(Encoder signal: invalid)When the encoder is used(Encoder signal: valid)13241 Interval (MarkingInterval): Inputs the moving distance of the line for marking start.Setting Range 0 to 3000.0 mm2 Line Speed : Inputs the line speed. Available when encoder setting is disabled.Setting Range 0.060 to 170.000 m/minutes (LP-M500 / LP-Z130)*0.060 to 240.000 m/minutes (LP-S500)** For the setting range of the other model, refer to “Input Setting Value by Series” (P.296).3 Delay Distance : Inputs the moving distance of line from trigger input to the start of marking.Setting Range 0 to 500.00 mmA A ADelay DistanceMarking Trigger ONMoving DirectionSensor Marking Interval Marking IntervalReference• Set a delay distance shorter than a marking interval.4 Encoder Signal : Enable this function when using the encoder. The setting parameter for the line speedis disappeared from the screen and the parameter for encoder pulse number appearsinstead when pressing the box.When the encoderis not used: Performs marking to flying object by applying the calculated linespeed already input.When the encoderis used: Performs marking to flying object by applying the calculated linespeed which is derived from the pulse sent from the encoderinput to the input terminal.ME-LPMSZ-OP-7