269ERRORCODE Error description MeasuresE220 Internal shutter error.• Connect head control cable properly, andrestart with key switch.• Contact to our sales office.E233Laser error.• The internal temperature of the laser oscillatorexceeds the limit.• Instantaneous interruption of laser power supply isdetected.• Head control cable is not connected properly.• Fiber is broken.• The abnormality of the laser oscillator is confirmed.• There might be occurred the malfunction of theinternal shutter.• Check that the ambient temperature is in thespecified operating temperature.• Check the air filter, the air intake / exhaust portand the fan of the cooling part for clogging.• Check and correct the power status.• Check the noise influence to the AC powersupply from the other devices.• Connect the head power cable and the headcontrol cable properly, and restart with keyswitch.• When not recovered, contact our sales office.E234 Detected unintended- irradiation. Contact to our sales office.E236*4 Laser gate is not open, or laser error has occurred.• Check the control signal for opening/closingthe laser gate from the safety PLC or othersuch device.• Check the wiring and signal timing of [L-GATECL IN] of the laser gate terminal.• Refer to the measure of E233 “Laser error”.E240E241 The temperature of the laser has reached its limit.• Check that the ambient temperature is in thespecified operating temperature.• Make sure cooling fan operates.• When not recovered, contact our sales office.E250*3 Detected a decrease in power supply voltage.• Check and correct the power status.• Check the noise influence to the AC powersupply from the other devices.• Connect head power cable properly, andrestart with key switch.• When not recovered, contact our sales office.E260Interlock connector is opened.Test marking starts while interlock connector oncontroller is in OPEN status.Interlock on controller is in OPEN status. (in remotestatus)• Check wiring of the interlock input on thecontroller and contact of the switch.• Confirm operation logic of connection device.• Connect the interlock connector with the non-voltage contact.E280*1System error.• Z control module error.Restart the laser marker. When not recovered,contact to our sales office.E300 A head is not connected. Shut off a power and connect ahead.Connect head control cable properly, and restartwith key switch.E310 Unsupported head.Change either head or controller. • Connect head control cable properly, andrestart with key switch.• Check if head with correct model has beenconnected. If it is wrong, replace head orcontroller with correct one.E311System error.• Head control cable is not connected properly.• Wrong head has been connected to controller.E312 System error. Restart the laser marker. When not recovered,contact to our sales office.ME-LPMSZ-OP-7