173Description8 Laser Power Correction :Scan Speed Correction :Laser Pulse Cycle Correction (Except LP-SxxxW type) :Correction of each human readable characters for the laser power / scan speed / laser pulse cycle set at lasersetting.Setting Range of Laser Power Correction 0 to 999%Setting Range of Scan Speed Correction 1 to 999%Setting Range of Laser Pulse Cycle Correction 1 to 999%Reference• If the value of “Laser power correction” × “laser power” is equal to or larger than 100, the setting will be “100”.• Marking is not available when the laser power correction value is “0”.• If the corrected value exceeds the setting limit, the nearest upper or lower limit value of the each item is set.9 AUTO (except EAN/UPC code) :Pressing AUTO button automatically aligns the Human Readable Text at its optimal position.Reference• When “X” is set to the narrow element width, the marking characters are automatically aligned at its center position onthe center of the code 3X distance from bottom of the code (for 2D side of composite codes from the top), characterwidth: 5X, character height 6X, character interval 4.5X.10 CENTERING (except EAN/UPC code) :Pressing CENTERING button aligns the Human Readable Text to the center of the code.11 SET:Sets and conform the setting condition of Human Readable Text.12 CANCEL:Cancel the setting condition and close the Human Readable Text Setting screen.* For the setting range of the other model, refer to “Input Setting Value by Series” (P.296).Reference• The size and position of the human readable text of EAN/UPC codes are specified automatically based on thestandards.• “FNC1” and control codes are not shown in the human readable text at the marking.ME-LPMSZ-OP-7