№SR-ZSV00039 - 5 -Motor Business Unit, Appliances Company, Panasonic Corporation2-3 Input/Output Signal AllocationThe assignment of the input/output signals can be changed from the default setting.2-3-1 Allocation of Input SignalAn input signal that you wish can be assigned to an input pin of the I/F connectors. It is also possible to change thelogic.Note that for some signals, assignment is limited. For details, see (2) "Change the default assignment for inputsignals."(1) Use the default signal assignmentThe following table shows the default setting for the signal assignment.Default statusInput signals*2 CorrespondingparameterDefault value(): Decimalnumber Signal Logic *1SI1 input Pr4.00 00000003h(3) SRV-ON a connectSI2 input Pr4.01 00000004h(4) A-CLR a connectSI3 input Pr4.02 00000007h(7) CL a connectSI4 input Pr4.03 00000088h(136) INH b connectSI5 input Pr4.04 00000082h(130) NOT b connectSI6 input Pr4.05 00000081h(129) POT b connect*1 "a connect" and "b connect" represent the following respectively:a connect : A signal input is open with COM-, and thus the function is invalid (OFF state).A signal input is connected with COM-, and thus the function is valid (ON state).b connect : A signal input is open with COM-, and thus the function is valid (ON state).A signal input is connected with COM-, and thus the function is invalid (OFF state).In this specification, a signal input is defined ON when its function is valid; OFF when the function is invalid.*2 For pin numbers assigned as input signals SI1 – SI10, see Specifications.*3 The mark "-" displays that there is no function assigned.