Chapter 7 Appendix — Specifications178 - ENGLISHSpecificationsThe specifications of the projector are as follows.Power supply PT-RZ575 100 V - 240 V ~ (100 V - 240 V alternating current), 50 Hz/60 HzPT-RZ575T 110 V ~ (110 V alternating current), 60 HzPower consumption PT-RZ575 500 W (5.9 A - 2.3 A)PT-RZ575T 500 W (5.2 A)Power consumption (duringstandby)When [STANDBY MODE] is set to [ECO]: approx. 0.5 WWhen [STANDBY MODE] is set to [NORMAL]: approx. 10 WWhen [IN STANDBY MODE] in [AUDIO SETTING] is set to [ON], and the [QUICK STARTUP] function isdisabled: approx. 22 WWhen the [QUICK STARTUP] function is enabled: approx. 50 WDLP chipSize 17 mm (0.67") (aspect ratio 16:10)Display system DLP chip x 1, DLP projection systemNumber of pixels 2 304 000 pixels (1 920 x 1 200 dots)Lens Fixed: 0.8:1Electric focus: F = 1.75, f = 11.9 mmLight source LaserLight output 5 000 lm *1, 5 200 lm (center)*2(Both values are measured when [OPERATING MODE] is set to [NORMAL].)Contrast ratio*1 20 000:1 (when [DYNAMIC CONTRAST] is set to [ON])Color system 7 standards (NTSC/NTSC4.43/PAL/PAL-N/PAL-M/SECAM/PAL60)Projected image size 1.02 m (40") to 7.62 m (300")Image aspect ratio 16:10Projection method [FRONT/REAR]/[FLOOR/CEILING]Power cord length 3.0 m (118-1/8")Outer case Molded plasticDimensionsWidth 498 mm (19-5/8")Height 168 mm (6-5/8") (with the feet at shortest position)Depth 481 mm (18-15/16") (including lens)Weight Approx. 16.6 k] (36.5 lbs.)*3Noise level *1 33 dBOperatingenvironmentOperatingenvironmenttemperature0 °C (32 °F) to 45 °C (113 °F)*4Operatingenvironmenthumidity10 % to 80 % (no condensation)RemotecontrolPower supply DC 3 V (AAA/R03/LR03 battery x 2)Operating range Within approx. 30 m (98'5") (when operated directly in front of signal receiver)Weight 102 ] (3.6 ozs.) (including batteries)Dimensions Width: 48 mm (1-29/32"), Height: 145 mm (5-23/32"), Depth: 27 mm (1-1/16")*1 Measurement, measuring conditions, and method of notation all comply with ISO/IEC 21118:2012 international standards.*2 The value of the light output at the center region of the projected image is extracted based on the light output measurement method defined by theISO/IEC 21118:2012 international standards.*3 Average value. Weight varies for each product.*4 The operating environment temperature should be between 0 °C (32 °F) and 40 °C (104 °F) if the projector is used at an altitude between 1 400 m(4 593') and 4 200 m (13 780') above sea level. When the [PROJECTOR SETUP] menu → [OPERATION SETTING] → [OPERATING MODE] is setto [ECO], [SILENT], [LONG LIFE1], [LONG LIFE2], or [LONG LIFE3], the projector cannot be used at an altitude of 2 700 m (8 858') or higher abovesea level.When using the projector at an altitude lower than 2 700 m (8 858') above sea level, and the operating environment temperature becomes 35 °C(95 °F) or higher, the light output may be reduced to protect the projector. When using the projector at an altitude between 2 700 m (8 858') and4 200 m (13 780'), and the operating environment temperature becomes 25 °C (77 °F) or higher, the light output may be reduced to protect theprojector.Notef The model numbers of accessories and optional accessories are subject to change without prior notice.