AppendixA-4FrameSaver NP 110 User’s Manual - Installation Guide 980-001-0240BNovember 2000Device Fault Device Fault shows the highest priority hardware failure detected by the unit. This isdisplayed on the System View screen.DSX Port Fault DSX Port Fault shows the highest priority DSX Port fault currently detected. This isdisplayed on the System View, CSU / DSX Statistics Summary and Device Status /Test screens.Table A-2 Device FaultDisplay DescriptionNVM Failure Failure of NVM (Non-Volatile Memory) detected by the unit and the latestconfiguration may not have been saved.CSU Fault Failure of CSU related hardware detected by the unit.Single Flash Fail Failure of one of the unit’s two Flash Memory modules detected by the unit.SEEPROM Failure Failure of SEEPROM hardware detected by the unit.Table A-3 DSX Port FaultDisplay DescriptionDSX CFA/Red Alarm Detected loss of DSX Circuit Facility.DSX Rmt/Yellow Alarm Carrier alarm notification that Transmit failure from this DCE has been detected onthis DSX Circuit Facility.DSX AIS/Blue Alarm Carrier alarm notification that an upstream signal failure has been detected on thisDSX Circuit Facility.DSX Threshold Alarm Link Error Threshold reached or exceeded.