Technical Characteristics C3I12T11386 192-120113 N08 C3I12T11 - December 2010UL certification for Compax3Sconform to UL: according to UL508CCertified E-File_No.: E235342The UL certification is documented by a "UL" logo on thedevice (type specification plate).“UL” logo:UL-approval for PSUP/Compax3Mconform to UL: according to UL508CCertified E-File_No.: E235342The UL certification is documentedby a “UL” logo on the device (typespecification plate).Insulation requirementsEnclosure rating Protection class in accordance with EN 60664-1Protection against human contactwith dangerous voltages In accordance with EN 61800-5-1Overvoltage category Voltage category III in accordance withEN 60664-1Degree of contamination Degree of contamination 2 in accordance withEN 60664-1 and EN 61800-5-1Environmental conditions Compax3S and Compax3HGeneral ambient conditions In accordance with EN 60 721-3-1 to 3-3Climate (temperature/humidity/barometricpressure): Class 3K3Permissible ambient temperature:Operationstoragetransport0 to +45 °C class 3K3–25 to +70 °C class 2K3–25 to +70 °C class 2K3Tolerated humidity: no condensationOperationstoragetransport<= 85% class 3K3<= 95% class 2K3<= 95% class 2K3(Relative humidity)Elevation of operating site <=1000m above sea level for 100% load ratings<=2000m above sea level for 1% / 100m powerreductionplease inquire for greater elevationsMechanic resonances: EN 60068-2-6 (sinusoidal excitation)Sealing Protection type IP20 in accordance withEN 60 529