Parker EME Compax3 device description192-120113 N08 C3I12T11 - December 2010 45Maximum capacity in the axis system: PSUP10: 2400 μF PSUP20 & PSUP30: 5000 μFReference value for the required capacity in an axis system100 μF per kW of the temporal medium value of the total power (transmissions +power dissipation) in the axis systemExample: PSUP20 (1175 μF) with one axis controller (440 μF)Total power 15 kW, 100 μF/kW => 1500 μF required in the axis system.Axis system: 1615 μF are sufficient.Protective sealsCaution!The user is responsible for protective covers and/or additional safety measures inorder to prevent damages to persons and electric accidents.3.5.4. Control voltage 24VDC PSUP (mains module)Connector X9Pin Designation Line cross sections:minimum: 0.5mm 2 with conductor sleevemaximum: 6mm 2 with conductor sleeve(AWG: 20 ... 10)1 +24 V2 GND24VControl voltage 24 VDC PSUPDevice type PSUPVoltage range 21 - 27VDCRipple 0.5VppRequirement according to safe extralow voltage (SELV) yes (class 2 mains module)Current drain PSUP PSUP10: 0.2APSUP20 / PSUP30: 0.3AElectric current drain Compax3MC3M050D6: 0.853M100D6: 0.85AC3M150D6: 0.85AC3M300D6: 1.0 A+ Total load of the digital outputs + current forthe motor holding brake