Parker Hannifin S.p.A S.B.C. Division SLVDN User’s ManualPage 179 of 18120.Appendix G: External capacitorIn the terminal block X7 there are positive and negative poles of the intermediary DC circuitof the drive. Only for some models it’s possible to connect the external capacitors, to storage(all or part) of the kinetic energy of the motor instead of to use the braking resistor.Additional external capacitor:supplymodel1-phase 3-phaseSLVD1N No permittedSLVD2N No permittedSLVD5N No permittedSLVD7N No permittedSLVD10N No permitted 2200μF, 450VSLVD15N No permitted 2200μF, 450VSLVD17N No permitted 2200μF, 450VType of capacitor : Itelcond AYX-HR222X450DC1 or similar.Connections:use only stranded copper wire rated for 60/75°C, minimum 300Vmax length : 30cmminimum section : 4mm2 (AWG10)keep the cables of two poles +/- near (stranded if it’s possible) for to minimize the area ofcoil.