DT Etherlink IV User Manual- 73 -4.6.5.30 CommandThe command sets number of SHDSL interfaces system will operate with.For example: The MODE 1 in a four-channel unit disables channels 2,3 & 4.To setup this configuration parameter you should perform the following command sequence:1. Apply and confirm all configuration changes2. Issue MODE [N] command3. RESETAfter the reset unit will work with specified number of SHDSL channels.4.6.5.31 CommandThis command shows the active licenses.CP_CM>LICENSECurrent license status:Extended PAM and baserates: Not activated4.6.5.32 CommandThis command activate a special functionality added by a license KEY, that you can get from themanufacturer.4.6.5.33 CommandThis command defines the RS-232/RS-485 data format. [Format] means:Data bits: 5..8Parity: N, E, O, M, S N - None E - Even O - Odd M - Mark S - SpaceStop bits: 1, 1.5, 2CP_01_CM> RSFORMAT 8N14.6.5.34 This command sets the operating mode of the RS-485 interface: F means FULLDUPLEX H means HALFDUPLEX4.6.5.35 CommandThis command sets the transmission rate N for Nx64/RS-232/RS-485 interfaces.For the Nx64 interface: N=1…128 (V.35/V.36/X.21) or N=1…7 (V.28), in this case the Nx64 datarate will be Nx64 kbps.For the RS232 and RS485 interfaces: N is the baudrate (9600 for instance). N=1200…256000.4.6.5.36 CommandThis command sets the autoloop mode. OFF means line 141 is ignored