64This function returns all setting values except for User logo,PIN code lock, Logo PIN code lock, Lamp counter, and Filtercounter to the factory default settings.Various test pattern are available for use when setting up theprojector.Filter warning icon appears on the screen at aset time.Fig 1 Filter warning iconPNote:• Fig.1 appears at turning on and selecting inputsource.• Fig.1 will not appear when the Display function isset to Off (p.52), during “Freeze” (p.30) or No show(p 29).SettingThis function is used to set a frequency for the filter cartridgereplacement.Use the Point pq buttons to select Filter counter and then pressthe Point u or the SELECT button to access the submenu items.Filter counter...... Show the total accumulated time of the filtercartridge.Timer ................ To set a timer, when the projector reachesthe time, the Filter warning icon (Fig. 1)appears on the screen and the totalaccumulated time turns red, indicating thatthe filter cartridge replacement is necessary.Filter counter reset...When replacing the Filter cartridge, reset theFilter counter (p.67).Filter counterPress the SELECT button to select Timer and then usethe Point pq buttons to set the timer. Select from (Off/600H/900H/100H/1500H/100H/000H) depending onthe use environment.Filter counterTest patternFactory default