PLC-WU3800 Expand Serial Command Functional Specifications45/748.10.29 CF_FILTIMER CommandCommand “CF_FILTIMER_%1”[CR]%1“100” -------------------- Set 100 hours“200” -------------------- Set 200 hours“300” -------------------- Set 300 hours“OFF” ------------------- No warning display“UP” --------------------- Switch Filter timer forwardOff →100 → 200 → 300 → Off“DN” --------------------- Switch Filter timer backwardOff → 300 → 200 → 100Details Set timer of Filter warning display.Response Acceptable “000”[CR]Unacceptable “Error Code”[CR]8.10.30 CF_FILH CommandCommand “CF_FILH_%1”[CR]%1 “RST” ---------------Reset Filter used timeDetails Reset filter used timeResponse Acceptable “000”[CR]Unacceptable “Error Code”[CR]8.10.31 CF_FDEFAULT CommandCommand “CF_FDEFAULT_%1”[CR]%1 “RST”Details Set the value to Factory DefaultThis command is available in normal Power ON status.Response Acceptable “000”[CR]Unacceptable “Error Code”[CR]