PLC-WU3800 Expand Serial Command Functional Specifications53/749.5.5 CR_V – POS CommandCommand “CR_V - POS”[CR]Details Get Vertical Position valueResponseAcceptable “000_%a”[CR]%a “0000”~“nnnn”(nnnn = Total Line - Display Line)Unacceptable“Error Code”[CR] -------- When the command is invalid due tocondition such as Input source“?”[CR] ----------------------- When unclear command is received9.5.6 CR_DDOTS CommandCommand “CR_DDOTS”[CR]Details Get Display Dots valueResponseAcceptable “000_%a”[CR]%a “0256”~“nnnn”(nnnn = Total Dots – Horizontal Position value)Unacceptable“Error Code”[CR] -------- When the command is invalid due tocondition such as Input source“?”[CR] ----------------------- When unclear command is received9.5.7 CR_DLINE CommandCommand “CR_DLINE”[CR]Details Get Display Line valueResponseAcceptable “000_%a”[CR]%a “0100”~“nnnn”(nnnn = Total Line – Vertical Position value)Unacceptable“Error Code”[CR] -------- When the command is invalid due tocondition such as Input source“?”[CR] ----------------------- When unclear command is received9.5.8 CR_PCSTORE CommandCommand “CR_PCSTORE”[CR]DetailsGet Free/Stored status of MODE1 - MODE5 for PC AdjustEach data consists of 5 bytes.Each byte indicates the status of MODE1~MODE5 respectively.(F:Free S:Stored)ResponseAcceptable “000_%a”[CR]%a“FFFFF” ----------- All Free“SFFFF” ----------- MODE1 is Stored, others are Free:“FFFFS” ----------- MODE5 is Stored, others are Free“SSSSS” ---------- All StoredUnacceptable “Error code”[CR]