PLC-XC50/55 Expand Serial Command Functional Specifications37/678.10.14 CF_ON – STA CommandCommand “CF_ON STA_%1”[CR]%1“ON” --------------------------- Set Power On Start to ON“OFF” ------------------------- Set Power On Start to OFF“UP” --------------------------- Switch setting (On → Off → On → )“DN” --------------------------- Switch setting (On → Off → On → )Note) “UP” and “DN” behave the same.DetailsSet/Cancel Power ON StartThe status set by this command is stored in EEPROM and its setting is effectiveafter ALL is OFFThis command is available in normal Power ON status.Response Acceptable “000”[CR]Unacceptable “Error Code”[CR]8.10.15 CF_CCAPTIONDISP CommandCommand “CF_CCAPTIONDISP_%1”[CR]“OFF” ------------------------------ Select Off“CC1” ------------------------------ Select CC1“CC2” ------------------------------ Select CC2“CC3” ------------------------------ Select CC3“CC4” ------------------------------ Select CC4DetailsSwitch Closed Caption channels.The status set by this command is stored in EEPROM and its setting is effectiveafter ALL is OFF.This command is available in normal Power ON status.Response Acceptable “000”[CR]Unacceptable “Error Code”[CR]8.10.16 CF_CCAPTIONCOLOR CommandCommand “CF_CCAPTIOPNCOLOR_%1”[CR]“COLOR” ----------------------------- Select Color“WHITE” ------------------------------ Select WhiteDetailsSet up Closed Caption display color.The status set by this command is stored in EEPROM and its setting is effectiveafter ALL is OFF.This command is available when projector is in normal Power ON status and itscondition is; appropriate signal (NTSC signal from Video, S-video input orComponent (480i)) being transmitted and System setting is set to NTSC/480ifixed.Response Acceptable “000”[CR]Unacceptable “Error Code”[CR]8.10.17 CF_FILH CommandCommand “CF_FILH_%1”[CR]%1 “RST” ---------------Reset Filter used timeDetails Reset filter used timeResponse Acceptable “000”[CR]Unacceptable “Error Code”[CR]