PLC-XC50/55 Expand Serial Command Functional Specifications65/679.12.5 CR_PTIMER CommandCommand "CR_PTIMER”[CR]Details Get status of Presentation TimerResponseAcceptable “000_%a”[CR]%a“ON” -------------------- Presentation timer is in operation“STOP” ----------------- Presentation timer is paused“OFF” ------------------- Presentation timer is not operatingUnacceptable “Error Code”[CR]9.12.6 CR_TEMPWARN CommandCommand “CR_TEMPWARN”[CR]DetailsGet the temperature inside a projector and its condition if it is abnormaltemperature or close to abnormal temperatureIf there are several sensors installed, it is possible to get information from all thesensors at once.ResponseAcceptable “000_%a_%b_%c”[CR]%a%b%c%a -------------------- Sensor 1 status%b -------------------- Sensor 2 status%c -------------------- Sensor 3 status“W” ---- Approach or reach abnormal temperature(dangerous temperature)“S” ---- Far from abnormal temperature (safe temperature)“N” ---- Sensor detects no abnormal temperature[Example]“S_W_S”[CR] means Sensor 1 detects safe temperature, Sensor2 detects abnormal temperature and Sensor 3 detects safetemperatureNote) When the temperature difference between Sensor 1 and 3reaches specific value, some of the models detect it as Abnormaltemperature. In this case, the 3rd data shows if the temperaturedifference between Sensor 1 and 3 is dangerous state or not. The3rd data means temperature abnormality due to Sensor 3When abnormal temperature is not detected by sensor, “N” (Noconnection with temperature abnormality) is returned.Unacceptable “Error Code”[CR]