PLC-XC50/55 Expand Serial Command Functional Specifications38/678.10.18 CF_FILTIMER CommandCommand “CF_FILTIMER_%1”[CR]%1“400” -------------------- Set 400 hours“700” -------------------- Set 700 hours“1000” ------------------- Set 1000 hours“OFF” ------------------- No warning displayDetails Set timer of Warning display of Filter cleaning and Filter replacementResponse Acceptable “000”[CR]Unacceptable “Error Code”[CR]8.10.19 CF_FILCTL CommandCommand “CF_FILCTL_%1[CR]%1 “ROLL” --------------- Scroll the filter.Details Reset Filter Scroll counterResponse Acceptable “000”[CR]Unacceptable “Error Code”[CR]8.10.20 CF_FILSCRL CommandCommand “CF_FILSCRL_%1[CR]%1 “RST” ---------------Reset Scroll counterDetails Reset Filter Scroll counterResponse Acceptable “000”[CR]Unacceptable “Error Code”[CR]8.10.21 CF_RCODE CommandCommand “CF_RCODE_%1”[CR]%1"001” --------------------------- Select Code1"002” --------------------------- Select Code2“UP” --------------- Switch Code setting of Remote Control in positive order(Code1 → Code2 → Code1 )“DN” --------------- Switch Code setting of Remote Control in negative order(Code2 → Code1 → Code2 )DetailsSelect Code of Remote ControlThe status set by this command is stored in EEPROM and its setting is effectiveafter ALL is OFFThis command is available in normal Power ON status.Response Acceptable “000”[CR]Unacceptable “Error Code”[CR]8.10.22 CF_KEYDIS CommandCommand “CF_KEYDIS_%1”[CR]%1“NONE” ----------------------- RC & Projector keys are valid (All are valid)“RC” ---------------------------- RC keys are invalid“KEY” -------------------------- Projector keys are invalidDetails Disable RC/Projector keysThis command is available in normal Power ON status.Response Acceptable “000”[CR]Unacceptable “Error Code”[CR]