5 Replacing PartsFS100 5.1 Fuse Replacement5-15 Replacing Parts5.1 Fuse ReplacementWARNING• To prevent anyone inadvertently turning ON the power supply(including a pressurized air), put up a warning sign such as "DONOT TURN ON THE POWER" before the maintenance, inspection,or wiring operation.WARNING• Maintenance and inspections should be carried out by the qualifiedworker.Failure to observe this caution may result in electric shock or injury.Following fuses 1) are mounted in the FS100.Fuse name Where to mount Type ManufacturerI/O power supply fuse(F1: left side of the following figure)Front side of the FS100 0312.600, 250V, 0.6A6.3 dia. x 32 mm,fast-blow typeLittel Fuse Ltd.Fuse for regenerative resistor fanprotection 2)(F2: right side of the followingfigure)Front side of the FS100 250V, 1A5 dia. x 20 mmLittel Fuse Ltd.1 A fuse is delivered with the FS100 before shipment for replacement.2 Fuse for regenerative resistor fan protection is mounted on the FS100 for HP20Fonlly.