12.5 Traveling speed defaultsAfter entering the installation specifications and carrying out the automatic parameter assignment, thetraveling speeds "V_2" and "V_3" are pre-configured in the Travelling menu, dependent on "V*".Designation Parameter pre-signmentIntermediate speed V_2 V_2 50% V*Travel speed V_3 V_3 100% V*The speeds listed in the table below are permanently preset and thus independent of "V*".Designation Parameter pre-signmentPositioning speed V_1 0,05 m/sReadjustment speed V_Z 0.01 m/sAdditional speed V_4 V_4 0,32 m/sAdditional speed V_5 V_5 0,32 m/sAdditional speed V_6 V_6 0,32 m/sAdditional speed V_7 V_7 0,32 m/s12.6 Distance-dependent decelerationIn a path-dependent deceleration, the deceleration paths are always identical. Independent of thespeed reached at the start of the deceleration.The path-dependent deceleration can be activated in the menu Decelerating/S_ABH = ONPath dependent deceleration is carried out during deceleration of:• V3 R V1• V2 R V1• V3 R Drehzahl 0 (only in DCP2/DCP4 protocol)• V3 R Drehzahl 0 (only in DCP2/DCP4 protocol)During all other switchovers between two speeds, the deceleration is carried out time-dependent.InformationBefore removing the digital input for the travel speeds V_3 or V_2 the input for the travel speed V_1must be applied (see diagram "Normal stop at distance-dependent deceleration").If it is not possible to control two travelling speeds simultaneously for technical reasons (e.g. control ofthe speeds by an alternating contact), the distance-dependent delay with the Control system/SIM_-V1=ON parameter can be activated!Here it must be noted that the positioning speed V_1 must be activated 100 ms after deactivation ofthe travelling speeds V_3 or V_2 at the latest!If binary speed is specified, there is only a distance-dependent delay at Control system/SIM_V1=ON!InformationIf the high travelling speed signal is briefly switched off (e.g. V_3), the frequency inverter slows downthe motor to the positioning speed V_1. For safety reasons, further actuation of a greater travellingspeed is ignored. A greater travelling speed may only be actuated once all inputs for the travellingspeeds have been switched off and once the motor has reached the speed 0.12.6.1 Normal stop during path dependent deceleration6When the switch off point for the traveling speed is reached, the configured final speedV_3 has been reached.Deceleration is initiated7 Travel at positioning speed V_18 Positioning speed V_1 is switched off.Motor continues to decelerate.9Speed 0Output MB is switched offBrake must operate immediatelyThe motor continues to be fed with currentTranslation of the original operating instructionsZETADYN 4C Travel optionsR-TBA12_01-GB 1415 Part.-No. 00163371-GB108/204