5.14.3 Terminal assignment X-OUTThe output assignments can be configured. The configuration can be implemented by:• Presetting the used control system (assignment corresponding to the control requirements)• Free configurationImplement configuration of the digital outputs in the Control system\CONFIG menu.Please refer to the "Parameter list/Control menu" chapter for a description of the individual parametersThe output assignments dependent on the configuration:Configuration OutputsO11 - O14 O21 - O24 O31 - O34 O41 - O44 O51-- 5400:Free Fault* MB_Brake* MotContact* V < V_G1* STO-Info*01:ZA_IO Fault MB_Brake MotContact V < V_G1 STO-Info03:BP_IO Fault MB_Brake MotContact V < V_G1 STO-Info08:KN_IO Fault MB_Brake MotContact V < V_G1 STO-Info11:NL_IO Fault MB_Brake MotContact V < V_G1 STO-Info13:SS_IO Fault MB_Brake MotContact V < V_G1 STO-Info15:ZA_BIN Fault MB_Brake MotContact V < V_G1 STO-Info16:WL_IO Fault MB_Brake MotContact V < V_G1 STO-Info21:ST_IO Fault MB_Brake MotContact V < V_G1 STO-Info24:CSILVA Fault MB_Brake MotContact V < V_G1 STO-Info25:S+S MotContact MB_Brake V=O Fault STO-Info27:MAS_BIN Fault MB_Brake MotContact Off* STO-Info30:KS_IO Fault MB_Brake MotContact V < V_G1 STO-Info31:KL_IO fault MB_Brake MotContact EVAC.DIR STO-Info32: S_SMART Fault MB_Brake MotContact SD STO-Info* The function of the outputs can be changed5.15 DCP / CAN interface (X-DCP, X-CAN)As an alternative to the conventional wiring, it is possible to actuate the ZETADYN 4 via DCP orCANopen lift (see chapter "Serial communication").InformationThe X-DCP and X-CAN terminals are standard parts of the ZETADYN 4C.5.15.1 DCP• Use a shielded cable for the connection. The shielding must be grounded on the inverter side.• Make the connection between the ZETADYN 4 and the control without additional terminal points.• The maximum line length is 50 m.X-DCPDADB0VDDATA + (A)DATA - (B)GND(1)(2)(3)(4)DCP connection() terminal designation of connectorFor more detailed information on DCP, see chapter "Serial communication/DCP (Drive Control &Position)"Translation of the original operating instructionsZETADYN 4C Electrical installationR-TBA12_01-GB 1415 Part.-No. 00163371-GB33/2045 Electrical instal-lation