16.5.4 Saving parameters lists, printer lists and error listsParameter lists, printer lists and error lists can be saved on the memory card with allocation of theZETADYN 4 serial number.The following folder structure is created on the memory card: "4CX\DEVICE\serial number". The"LST" and "PAR" folders are created in the "Serial Number" folder. The error lists and printer lists aresaved in the "LST" folder, the parameter lists are saved in the "PAR" folder. The lists are namedaccording to the actual number of runs at the time of the data backup (e.g. "00000109.FLT" with 109runs).Loading parametersStatistics->Memory CardMMC RecorderEncoder-adjust.Select "Memory Card" menuConfirming menu selectionMemory Card|-" SAV_ALL OFF|-" ONSelect "SAV_ALL" parameterConfirming menu selectionSelect "SAV_ALL=EIN"Confirm with the key.Copy1:_ _ _ _ _ _ _ _ _The parameter list, the printer list and the error list are saved.Memory Card-> SAV_ALL OffSAV_PAR OffAfter the data backup the "SAV_ALL" parameter reassumes the value"OFF".16.5.5 Performing measurementsIt is possible to perform measurements on the ZETADYN 4. These measurements are configured inthe MMC-Recorder menu and can be saved on the memory card. A description of the individualparameters of the MMC-Recorder menu can be found in the chapter "Parameter List / Menü MMC-Recorder". The following folder structure is created on the memory card: "4CX\DEVICE\serial num-ber\Rec". A sub-folder is created in the "Rec" folder for every measuring variant. The measurementsare saved in these sub-folders. The following sub-folders can be created:• "ERR"folder: Save measurements which were interrupted by occurrence of an error.• "NORM"folder: Save measurements for runs without errors.• "SHOT"folder: Save measurements which were made with the "Stop&Shot" function.The actual number of runs is used as a file name (e.g. "00000109.ZR3" for 109 runs).16.5.6 Saving configurationsThe configurations of parameters can be saved on the memory card by allocating configurationnumbers. The parameter list and the printer list are saved. The following folder structure is created onthe memory card: "4CX\CONFIG\configuration number". Parameter lists are saved with the fileextension ".PA4" and printer lists with the file extension ".PRT".InformationIf two configurations are saved under the same configuration number, the existing configuration isoverwritten.Translation of the original operating instructionsZETADYN 4C Special functionsR-TBA12_01-GB 1415 Part.-No. 00163371-GB168/204