Error no. Error text Error cause M S830 CAN: Timeout Enab.-Det.Error:Control system gives command "Enable Operation" not within T_CMDAdjustment:Increase time for T_CMD831 CAN: Timeout Dis. Op. Error:Control system gives command "Disable Operation" not within T_CMDAdjustment:Increase time for T_CMD832 CAN: Timeout Shut-downError:Control system gives command "Shutdown" not within T_CMD. Occurs byclosing the brakes.Adjustment:Increase time for T_CMD833 CAN: Timeout Dis. Vol. Error:Control system gives command "Disable Voltage" not within T_CMD. Occurs atend of travel.Adjustment:Increase time for T_CMD840 CAN: ENC. Info missing Error:The object "Encoder Info" was not written to the frequency inverter by thecontrol14.5.11 Error 9xx• Fatal errors which can only be acknowledged by switching off the ZETADYN 4Error no. Error text Error cause M S905 MOP:HW-SW Error Error: Hardware or software error occurred after switch-on. After 60 s, thefrequency inverter switches to "Wait-Switch off"Remedy:Check the connectors between the Control Unit and Modul Printcheck the fuse on the Switching Power Printno Modul Print existingcheck EEprom on the Modul Print906 ZR_ERR by start Error: No signal at BC input during ZETADYN 4 start-upRemedy: Check wiringUse the ZArec display to check for an error at the ZArec908 PFU: No function Error:When switching on the frequency inverter, the monitor contact of thepower feedback unit is not closedRemedy: Check connection of the feedback unit function monitor,Check feedback unit function monitor●910 BC: No function Error: When switching on the frequency inverter, the monitor contact for thebrake chopper or brake resistor is not closedRemedy: Check the temperature monitor for the Brake-Chopper or Brakeresistor,check the temperature monitoring for the Brake-Chopper or Brake-Resistor,911 BRxx: Overload Error: The continious braking power of the Brake resistor is exceeded by 150% within 120 sThe frequency inverter switches off during travelRemedy: Check the configuration of the BR-typeCheck the connected BR●912 BC: Fault Error: Monitor contact for brake chopper or brake resistor opens during fre-quency inverter operationRemedy: Check the temperature monitor for the Brake-Chopper or Brakeresistor,check the temperature monitoring for the Brake-Chopper or Brake-Resistor,Translation of the original operating instructionsZETADYN 4C Error diagnosisR-TBA12_01-GB 1415 Part.-No. 00163371-GB143/20414Error diagnosis