14.5.2 Block functionBlocks the controller if certain errors occur several times is succession. The errors must occur indirectly consecutive travel tests. The fault counter is set to 0 when performing a trouble-free run.The following block functions can be set in the Monitoring / MOD_ST menu:• Fix 2 Sec.: No blocking function, the output configured on "ST" drops for 2 seconds during amalfunction and then increases again (speed preset V_x must be switched off)• Lock n.3: Lock function after 3 malfunctions. Output "ST" remains dropped after the 3rd error• Lock n.2: Lock function after 2 malfunctions. Output "ST" remains dropped after the 2rd error• Lock n.1: Lock function after 1 malfunction1. Output "ST" remains dropped after the 1st errorErrors which lead to disabling of the ZETADYN 4 are marked by a dot in the S column.14.5.3 Notes 0xxInformation about:• Error memory content• Changes in the operating conditions• Application of special frequency inverter functionsNote-No. Note text Description M SN0 Memory empty EEPROM is emptyN010 Update software Software update was carried outAdditional information: Version of the new softwareN020 MOT_TYP changed Motor type in "Motor name plate" was changedN077 ST_LST: locked Five faults occurred in direct successionFault memory is blockedAdditional information: indicates the most recent faultThe fault counter is set to 0 when performing a trouble-free run.●N080 Mode: EVA ->Norm Switchover from evacuation to normal mode was implementedN081 Mode: Norm ->EVA Switchover from normal to evacuation to mode was implementedN082 Mode:ParaChange The parameter set was changed ●N085 Mode: Safety Br Safety brake function was implemented ●N086 Mode:Enc.Adj.MB Encoder-alignment with closed brakes was carried outN087 Mode:Encoder-Adj. Manual encoder offset was carried outN088 Mode:Encoder-Check The encoder offset alignment was checked14.5.4 Error 1xx• Hardware configuration error• Software errorError no. Error text Error cause M S100 Serial no. missing Frequency inverter/CU does not have a serial number, e.g. after a componentreplacement●101 System-Error A defective internal component was identified during a self-test of the fre-quency inverter●110120 CU: No ID CU ID no. was not detected:CU is not present or its ID EEPROM does not reply●111 CUSH: No ID Shunt ID no. was not detected:Shunt module is not present or its ID EEPROM does not reply●113123 CUEE: No ID ID no. of the extension card for the rotary encoder was not detected: extensionmodule is not present or its ID EEPROM does not reply●115125 SP: No ID Switching power supply ID no. was not detected: Switching power supply is notpresent or its ID EEPROM does not reply●116126 PP: No ID Power print ID no. was not detected:Power print is not present or its ID EEPROM does not reply●Translation of the original operating instructionsZETADYN 4C Error diagnosisR-TBA12_01-GB 1415 Part.-No. 00163371-GB132/204