Parameter Description Value range Factorysettingvisible inthe basiclevelST_SRF Number of travel aborts due to interruption of the controllerenable RF during the travel Cannot be set - XST_SXO Number of travel interruptions due to interruption of the STO orCO input signal during travel operation Cannot be set - XST_CRL Delete error memoryDeletes ST_LST, ST_RES and ST_SRF and ST_SCO Cannot be set -APD Automatic parameter diagnosis, see "Error diagnosis" chapterOn: Automatic parameter diagnostics are activatedOff: Automatic parameter diagnostics are deactivatedOnOff OffRESET Deletes parameters, counter levels and error lists, preassigningparameters with standard values.RESET77:Pre-parameterised ZETADYN 4: Parameters are assigned cus-tomer-specific system dataStandard ZETADYN 4: Parameters will be set with standarddataRESET90: Device reset, parameters remain preserved. ENC_-OFF stays.RESET99: Device reset, parameters deleted and assigned bythe factory settings.If a value is entered for the rotary encoder offset (ECOFF), it willalso be deleted!Reset 77Reset 90Reset 990 XTD_PWN Assign password for the travel direction counter.A number between 0 and 9999 can be used as a password 0 ... 9999 0TD_PWC Displays the password in coded form. If you lose the password,please contact the manufacturer. nicht einstellbar 21689TD_PW Enter password. 0 ... 99990 = no password 0TD_CNT Initial value of the down counterIf the start value of the down counter is set to 0.00, the downcounter is deactivated.0.00 ... 10.00 M 0.00TD_RST Restore the counter level from the rotary encoder OnOff Off11.16 Memory Card menuContains the parameters for the various functions in association with a memory card.InformationNot all parameters are visible when the Memory Card menu is opened in the basic level.Parameter Description Value range Factorysettingvisible inthe basiclevelSAV_ALL Saves data to memory card with serial number allocation• Parameter list (.PRT) in directory /4BF/DEVICE/seriealnumber/LST• Error list (.FLT) in directory /4CX/DEVICE/serial number/LST• Parameter (.PA3) in directory /4CX/DEVICE/serial number/-PAR• Black-Box (.BOX) in directory /4CX/DEVICE/serial num-ber/LSTOff: no functionON: Data will be saved to the memory card. After copying, theparameter jumps back to "Off"OnOff Off XTranslation of the original operating instructionsZETADYN 4C Parameter listR-TBA12_01-GB 1415 Part.-No. 00163371-GB89/20411Parameter list