Zeiss Axiolab 5 manuals
Axiolab 5
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- INTRODUCTION
- Warning labels on the microscopes
- Fig. 1-2 Warning labels on the Axiolab 5 stand for transmitted light
- Notes on the warranty
- DESCRIPTION OF THE INSTRUMENT
- Technical data
- Interface diagram
- Control and functional elements on the microscope
- Axiolab 5 stand, Bio-TL
- Fig. 2-2 Axiolab 5 stand, Bio-TL
- Axiolab 5 stand, Bio-TL/FL
- Fig. 2-3 Axiolab 5 stand, Bio-TL/FL
- Axiolab 5 stand, Pol-TL
- Fig. 2-4 Axiolab 5 stand, Pol-TL
- Axiolab 5 stand, Pol-TL/conoscopy
- Fig. 2-5 Axiolab 5 stand, Pol-TL/Conoscopy
- Axiolab 5 stand, Pol-TL/RL
- Fig. 2-6 Axiolab 5 stand, Pol-TL/RL
- Axiolab 5 stand, Mat-TL/RL
- Fig. 2-7 Axiolab 5 stand, Mat-TL/RL
- Functions of stands keys and display elements
- Control and functional elements on microscope components
- Fig. 2-10 Binocular photo tube 30°/23 with toggle graduation 100:0/0:100
- Fig. 2-11 Binocular ergo photo tube 20°/23 with vertical adjustment
- Microscope stages
- Filter mount on luminous-field diaphragm operating ring for filter 32x4 mm
- Filter slider for reflected light stand
- Polarizer
- Microscope operating modes
- Axiocam 202 mono/208 color controls and connectors
- OSD functionality with Axiocam 202 mono/208 color
- START-UP
- Fig. 3-2 Placing tools in the storage compartment
- Attaching the binocular tube/photo tube
- Inserting eyepieces or auxiliary microscope or pinhole diaphragm
- Screwing in objectives
- Inserting and removing P&C reflector modules in/from the reflector turret
- Mounting a mechanical stage
- Fig. 3-9 Friction adjustment
- Mounting the Pol rotary stage
- Fig. 3-11 Centering the Pol rotary stage
- Fig. 3-12 Centering objectives
- Mounting the condenser
- Mounting the darkfield condenser
- Mounting or replacing the 35 W halogen lamp or the 10 W LED illuminator for transmitted light
- Fig. 3-17 Removing the LED illuminator
- Fig. 3-19 Inserting the LED illuminator
- Mounting or replacing the 35 W halogen lamp or the 10 W LED illuminator for reflected light
- Fig. 3-22 Swinging the loops out
- Fig. 3-24 Changing the LED illuminator in the adapter
- Installing or replacing the LED modules for reflected light fluorescence
- Mounting the Axiocam 202 mono or Axiocam 208 color
- Mounting optional components
- Mounting and centering the low-power system for the objectives 2.5x/4x
- Inserting the modulator disk in the condenser 0.9 BF Pol
- Switching the microscope on/off
- Using the Light Manager function
- Default factory settings of the microscope
- OPERATION
- Adjusting for ametropia (user's visual impairment) when using eyepiece reticles
- Illumination and contrast methods in transmitted light
- Fig. 4-3 Microscope settings in transmitted light brightfield microscopy
- Fig. 4-4 Setting the height stop on the condenser carrier
- Configuring transmitted light darkfield microscopy using the KÖHLER method
- Configuring transmitted light phase contrast microscopy
- ring (dark-colored, in the object)
- Configuring transmitted light polarization microscopy
- Fig. 4-7 Components for transmitted light polarization
- Fig. 4-9 Schematic diagram of the color charts developed by Michel-Lévy
- Fig. 4-10 Components for circular polarization contrast
- Configuring transmitted light polarization with the conoscopy stand
- Fig. 4-12 Determining optical character
- Fig. 4-13 Components for transmitted light polarization on the conoscopy stand
- Fig. 4-15 Schematic diagram of the color charts according to Michel-Lévy
- Fig. 4-16 Components for circular polarization contrast on conoscopy stand
- Configuring transmitted light polarization for conoscopic observation – determining the optical character of crystals
- Fig. 4-17 Axiolab 5 for transmitted light conoscopy
- Fig. 4-18 Determining the optical character
- Illumination and contrast methods in reflected light
- Fig. 4-19 Microscope settings in reflected light brightfield microscopy
- Configuring reflected light darkfield microscopy
- Configuring reflected light polarization – Proof of bireflectance and reflexion pleochroism
- Setting reflected light fluorescence
- Fig. 4-20 Components for reflected light fluorescence
- CARE, FUSE REPLACEMENT AND SERVICE
- Instrument maintenance
- Troubleshooting
- Axiocam 202/208
- Maintenance and repair
- APPENDIX
- Index
- Industrial property rights
Related products
Axiolab AAxiolab PolAxioscope 5Axio Observer 5Axioscope 5 VarioAxioscope 5/7 MATAxioskopAxiotechAxiovert 5 digitalAxioskop 2Zeiss categories
Microscope
Binoculars
Medical Equipment
Lenses
Measuring Instruments
Laboratory Equipment
Camera Lens
Monocular
Digital Camera
Riflescope
manualsdatabase
Your AI-powered manual search engine