Manuals database logo
manualsdatabase
Your AI-powered manual search engine

Dell PowerEdge FX2s manuals

PowerEdge FX2s first page preview

PowerEdge FX2s

Brand: Dell | Category: Server
PowerEdge FX2s first page preview

PowerEdge FX2s

Brand: Dell | Category: Enclosure
Table of contents
  1. Table Of Contents
  2. Table Of Contents
  3. Table Of Contents
  4. getting help
  5. About your Dell PowerEdge FX2/FX2s
  6. Sled slot numbering
  7. Front panel features and indicators—PowerEdge FX2/FX2s
  8. Diagnostic indicators
  9. Power button functions
  10. KVM features
  11. Power supply unit indicators
  12. I/O module indicators
  13. CMC module
  14. Cooling fan indicator codes
  15. Configuration wizard
  16. Documentation matrix
  17. Accessing system information by using QRL
  18. Initial system configuration
  19. Logging in to the CMC
  20. PowerEdge FX2/FX2s mapping configurations
  21. I/O module port mapping—four-bay chassis
  22. I/O module port mapping—eight-bay chassis
  23. I/O module port mapping—six-bay chassis
  24. I/O module port mapping—two-bay chassis
  25. I/O module and PCIe mezzanine card configuration guidelines
  26. Configuring network settings for the I/O module
  27. PCIe slot mapping from compute sleds mapped to storage sleds
  28. Managing PCIe slots
  29. components
  30. Before working inside your system
  31. Installing the system cover
  32. Sleds
  33. Installing a compute sled
  34. Removing a storage sled
  35. Installing a storage sled
  36. Inside the system
  37. Installing the CMC module
  38. I/O module
  39. Installing an I/O module
  40. Removing a PCIe module
  41. Installing a PCIe module
  42. PCIe module indicators
  43. Removing an expansion card
  44. Installing an expansion card
  45. Removing a power supply unit
  46. Installing a power supply unit
  47. Installing a cooling fan
  48. Installing the cooling-fan cage
  49. Installing the PCIe switch board
  50. Removing the fan interface board
  51. Installing the fan interface board
  52. Interposer module
  53. Removing the bottom interposer module
  54. Installing the bottom interposer module
  55. Removing the top interposer module
  56. Installing the top interposer module
  57. Midplane assembly
  58. Installing the midplane assembly
  59. Power interposer board
  60. Control panel
  61. Installing the control panel
  62. KVM panel
  63. Installing the KVM panel
  64. Troubleshooting your system
  65. Troubleshooting enclosure components
  66. Troubleshooting cooling problems
  67. Troubleshooting expansion cards
  68. Technical specifications—PowerEdge FX2/FX2s
  69. Power specifications
  70. Chassis Management Controller (CMC) specifications
  71. Expanded operating temperature
  72. Getting help
PowerEdge FX2s first page preview

PowerEdge FX2s

Brand: Dell | Category: Controller
Table of contents
  1. Table Of Contents
  2. Table Of Contents
  3. Table Of Contents
  4. Table Of Contents
  5. Table Of Contents
  6. Table Of Contents
  7. Table Of Contents
  8. Table Of Contents
  9. Overview
  10. What is new in this release
  11. Security features
  12. Supported remote access connections
  13. Supported platforms
  14. Supported firmware versions
  15. Managing licenses
  16. Types of licenses
  17. Licensable features in CMC
  18. Viewing localized versions of the CMC web interface
  19. Accessing documents from Dell support site
  20. Installing and setting up CMC
  21. Daisy chain FX2 CMC network connection
  22. Using remote access software from a management station
  23. Remote RACADM installation
  24. Uninstalling remote RACADM from a Linux management station
  25. Downloading and updating CMC firmware
  26. Configuring LEDs to identify components on the chassis
  27. Configuring chassis management at server mode
  28. Logging into CMC
  29. Generating public keys for systems running Linux
  30. Logging into CMC using a smart card
  31. Logging into CMC using Single Sign-On
  32. Multiple CMC sessions
  33. Updating firmware
  34. Viewing currently installed firmware versions using RACADM
  35. Updating CMC firmware using RACADM
  36. Updating chassis infrastructure firmware using RACADM
  37. Updating server component firmware
  38. Enabling Lifecycle Controller
  39. Viewing firmware inventory
  40. Saving chassis inventory report using CMC web interface
  41. Lifecycle Controller job operations
  42. Viewing chassis information and monitoring chassis and component health
  43. Viewing server model name and Service Tag
  44. Viewing information and health status of the IOMs
  45. Configuring fans
  46. Configuring CMC
  47. Enabling or disabling DHCP for DNS IP addresses
  48. Viewing and modifying CMC network LAN settings
  49. Configuring auto negotiation, duplex mode, and network speed (IPv4 and IPv6)
  50. Configuring Management Port 2 using RACADM
  51. Enabling FIPS Mode Using RACADM
  52. Configuring CMC extended storage card
  53. Adding members to Chassis Group
  54. Disabling an individual Member at the Member chassis
  55. Synchronizing a new Member with Leader chassis properties
  56. Chassis Configuration Profiles
  57. Viewing Stored Chassis Configuration Profiles
  58. Editing Chassis Configuration Profiles
  59. Importing Chassis Configuration profiles
  60. Parsing rules
  61. Modifying the CMC IP address
  62. Configuring servers
  63. Configuring iDRAC network settings
  64. QuickDeploy IP address assignments for servers
  65. Modifying iDRAC Network Settings for individual server iDRAC
  66. Configuring iDRAC VLAN tag settings using web interface
  67. Setting first boot device for multiple servers using CMC web interface
  68. Configuring sled network uplink
  69. Configuring profile settings using server configuration replication
  70. Adding or saving profile
  71. Importing profile
  72. Viewing profile settings
  73. Quick Deploy of profiles
  74. Saving Boot Identity Profiles
  75. Clearing Boot Identity Profiles
  76. Deleting Boot Identity Profiles
  77. Removing MAC Addresses
  78. Launching iDRAC from Server Status
  79. Configuring storage sleds
  80. Configuring storage sleds using RACADM
  81. Configuring CMC to send alerts
  82. Configuring e-mail alert settings
  83. Configuring user accounts and privileges
  84. Modifying root user administrator account settings
  85. Configure local users using RACADM
  86. Configuring standard schema Active Directory
  87. Configuring extended schema Active Directory
  88. Configuring generic LDAP directory service using RACADM
  89. Configuring CMC for Single Sign-On or Smart Card login
  90. Prerequisites for Single Sign-On or Smart Card login
  91. Mozilla Firefox
  92. Uploading Keytab file
  93. Configuring CMC to use Command Line consoles
  94. Using SSH with CMC
  95. Configuring terminal emulation software
  96. Configuring the managed server BIOS for serial console redirection
  97. Configuring Windows for serial console redirection
  98. Configuring Linux for server serial console redirection after boot
  99. Managing CMC using iDRAC RACADM proxy
  100. Using FlexAddress and FlexAddress Plus cards
  101. Verifying FlexAddress activation
  102. Deactivating FlexAddress
  103. Command messages
  104. FlexAddress DELL SOFTWARE LICENSE AGREEMENT
  105. Viewing WWN/MAC address information
  106. Viewing basic WWN/MAC address information using web interface
  107. Viewing WWN/MAC address information using RACADM
  108. Managing Fabrics
  109. Configuring network settings for IOM using RACADM
  110. Updating IOM software using CMC web interface
  111. Launching IOA/MXL GUI from the I/O Module Overview
  112. Using VLAN Manager
  113. Viewing the VLAN settings on IOMs using CMC web interface
  114. Resetting VLANs for IOMs using CMC web interface
  115. Managing and monitoring power
  116. Grid Redundancy policy
  117. Viewing power consumption status using CMC web interface
  118. Configuring power budget and redundancy
  119. Executing Power Control Operations
  120. Executing Power Control Operations on the IOM
  121. Configuring PCIe slots
  122. Viewing PCIe slot properties using CMC web interface
  123. Troubleshooting and recovery
  124. Downloading SNMP Management Information Base (MIB) file
  125. Troubleshooting Alerts
  126. Resetting Components
  127. Interpreting LED colors and blinking patterns
  128. Troubleshooting Network Problems
  129. Resetting Forgotten Administrator Password
  130. Frequently asked questions
  131. Active Directory
  132. Event and error messages
Related products
PowerEdge FX2PowerEdgePowerEdge 5/iPowerEdge 2850PowerEdge 2650PowerEdge 2800PowerEdge C6145PowerEdge SeriesPowerEdge M1000ePowerEdge PERC 6/E
Dell categories
More Dell categories
Manuals database logo
manualsdatabase
Your AI-powered manual search engine