296 V7122 GatewayUser GuideThe TP-260 and TP-1610 do not provide an RS-232 port.To establish a serial communications link with the gateway using the RS-232 port:1 Connect the RS-232 port to your PC (For the V7122 / TP-1610, see Connecting the RS-232 Port to Your PC.2 Use a serial communication software (for example, HyperTerminalTM) with the followingcommunications port settings: Baud Rate: 115,200 bps Data bits: 8 Parity: None Stop bits: 1 Flow control: NoneAfter resetting the gateway, the information, shown in Figure 86, appears on theterminal screen. This information can be used to determine possible V7122initialization problems, such as incorrectly defined (or undefined) local IP address,subnet mask, and the like.Figure 86 RS-232 Status and Error MessagesMAC address = 00-90-8F-01-00-9ELocal IP address = 10.1.37.6Subnet mask = 255.255.0.0Default gateway IP address = 10.1.1.5TFTP server IP address = 10.1.1.167Boot file name = ram35136.cmpINI file name = gateway.iniCall agent IP address = 10.1.1.18Log server IP address = 0.0.0.0Full/Half Duplex state = HALF DUPLEXFlash Software Burning state = OFFSerial Debug Mode = OFFLan Debug Mode = OFFBootLoad Version 1.75Starting TFTP download... Done.Mediant 2000 Version 4.60.00Automatic Update MechanismgThe Automatic Update mechanism is applied separately to each file. For the detailed list ofavailable files and their corresponding parameters, see Table 36.