Actual signals and parameters12985.08 CONSTANT8 Sets a constant for the Adaptive Program.-8388608 to 8388607 Integer value. 1 = 185.09 CONSTANT9 Sets a constant for the Adaptive Program.-8388608 to 8388607 Integer value. 1 = 185.10 CONSTANT10 Sets a constant for the Adaptive Program.-8388608 to 8388607 Integer value. 1 = 185.11 STRING1 Stores a message to be used in the Adaptive Program (EVENT block).MESSAGE1 Message. -85.12 STRING2 Stores a message to be used in the Adaptive Program (EVENT block).MESSAGE2 Message. -85.13 STRING3 Stores a message to be used in the Adaptive Program (EVENT block).MESSAGE3 Message. -85.14 STRING4 Stores a message to be used in the Adaptive Program (EVENT block).MESSAGE4 Message. -85.15 STRING5 Stores a message to be used in the Adaptive Program (EVENT block).MESSAGE5 Message. -90 DATASET INPUT SEL Addresses of the parameters into which the received fieldbus data arewritten. Refer to Table 2 on page 147 for more default information.90.01 DATA 1 WORD 1 Pointer for the parameter to which the value of the fieldbus is written.Note: A connection for the fieldbus main command word ishardcoded in the program. If a signal other than this is sent to thislocation, ensure that no parameters are set to FIELDBUS (that use06.01 DATASET 1 WORD 1).0…10000 Setting range. 1 = 190.02 DATA 1 WORD 2 Pointer for the parameter to which the value of the fieldbus is written.Note: A connection for the external reference is hardcoded in theprogram. If a signal other than this is sent to this location, ensure that11.03 EXT1 REF SELECT is not set to FIELDBUS.0…10000 Setting range. 1 = 190.04 DATA 3 WORD 1 Pointer for the parameter to which the value of the fieldbus is written.Note: A connection for the web tension setpoint is hardcoded in theprogram. If a signal other than this is sent to this location, ensure thatneither 62.10 DANCER LOAD SETPT nor 63.10 TENSIONSETPOINT are set to FIELDBUS.0…10000 Setting range. 1 = 190.05 DATA 3 WORD 2 Pointer for the parameter to which the value of the fieldbus is written.Note: A connection for tension taper is hardcoded in the program. Ifa signal other than this is sent to this location, ensure that TAPER REFSELECT (62.12 or 63.12) is not set to FIELDBUS.0…10000 Setting range. 1 = 190.06 DATA 3 WORD 3 Pointer for the parameter to which the value of the fieldbus is written.Note: A connection for the core speed match value is hardcoded inthe program. If a signal other than this is sent to this location, ensurethat 61.01 SPD MTCH REF SEL is not set to FIELDBUS.0…10000 Setting range. 1 = 190.08 DATA 5 WORD 2 Pointer for the parameter to which the value of the fieldbus is written.No. Name/Value Description FbEq