NoteActionArt. no. is specified in Requiredequipment on page 195.xx1000001439Insert the shims in the space between the tilt-house and the upper arm on the axis 3 side.CAUTIONDo not insert the shims too deep! If it is insertedtoo deep, it will be clamped up by the shaft.xx0600002748• Shims, T = 2 mm• A: 86 mm12Start pressing the parts together by screwingthe nut with a wrench, in order to verify that theshaft is getting correctly guided into the axis.13Then press the parts together with hydraulics.NoteRemember to move the shims and in-sert it on the axis 2 side.Fit the axis 2 side in the same way, by followingthe steps above.14Refitting lock nuts and the remaining partsBefore starting this procedure, perform the procedure:• Refitting shafts on page 206Use this procedure to refit the lock nuts and the other remaining parts of thetilthouse unit.NoteActionNoteStart the assembly on the axis 2 side!1Apply locking liquid (Loctite 243) on the threadsof the lock nut on the axis 2 side.2Tightening torque:• 90 NmSecure the axis 2 shaft with the lock nut.NoteFlat side of the lock nut facing inwards!3Continues on next pageProduct manual - IRB 760 2093HAC039838-001 Revision: M© Copyright 2011-2018 ABB. All rights reserved.4 Repair4.4.2 Replacing the tilthouse unitContinued