3-12container Commandscontainer create mstripeTo create a multilevel stripe set from equally sized arrays, use thecontainer create mstripe command. The top level of amultilevel stripe array can only be a stripe set. You can create thefollowing types of multilevel stripe set: Stripe set of mirror sets Stripe set of volume sets Stripe set of stripe sets Stripe set of RAID 5 arrays (a RAID-50 set)NotesWhen creating a multilevel array of stripe sets on a NetWare server,you specify the container IDs (as described in the Parameterssection) for the arrays from which you want to create the multilevelstripe set. If NetWare is using any of these arrays, an appropriatemessage displays. This message indicates that one or more of thearrays you specified is in use by NetWare. The message directs youto remove any NetWare volumes and partitions from these arrays.You can then create a multilevel array of stripe sets on a NetWareserver.After you create a multilevel array of stripe sets you can run thelist devices command on the NetWare console to verify itscreation and then create the necessary NetWare disk partitions andvolumes.For information on how to create partitions and volumes, see theappropriate NetWare documentation.Syntaxcontainer create mstripe [/stripe_size{=integer}][/label{=string}]{container} [{container}...]Parameters{container}Specifies the ID number (0 to 63) of the array from which youwant to create the multilevel stripe set.