FeaturesBasler sprint Color Cameras 2256.15.1 Saving the Work Set to a User Set FileAs mentioned above, the work configuration set is stored in the camera’s volatile memory and theparameter settings in the work set are lost if the camera is reset or if power is switched off. Thecamera can save the current work set values in the volatile memory to files in the camera’s non-volatile memory. Files in the non-volatile memory are not lost at reset or power off. There are fourfiles available for holding a saved user configuration set: UserSet01, UserSet02, UserSet03, andUserSet04. Saved configuration sets are commonly referred to as “user configuration sets” or “usersets.”Saving a User Configuration SetYou can save the current work set to one of the files in the non-volatile memory by using the CameraConfiguration Tool Plus (CCT+) or by using binary read/write commands from within your ownapplication to set the camera’s control and status registers (CSRs).With the CCT+With the CCT+ (see Section 7.1 on page 230), you use the File Name Select parameter and theCopy button in the User Set Files parameters group. Clicking the copy button will copy the work setsettings to the selected user set file in the non-volatile memory.By Setting CSRsYou can save the current work set settings to a file in the non-volatile memory by writing values tothe bulk data CSR for configuration sets.Section 7.2.3 on page 273 explains the bulk data CSRs and explains how to use the CSRs to savethe work set to a user set file. Section 7.3.1 on page 282 explains using read/write commands.NoteFor the 8k camera, only two user sets (UserSet01 and UserSet02) areavailable.