Configuring the Camera248 Basler sprint Color CamerasOffset CSRNote: The offset can be set by writing a floating point value to the Absolute Offset field or by writingan integer value to the Raw Offset field. See Section 7.2.2.1 on page 238 for an explanation of thedifference between these two fields.Register Base Address: 0x0F00Field Name: Register Status Offset: 0x0000 Size: 1 Byte Type: Read onlyDescription: The integer value in this field indicates the status of this control and status register:0x00 = The register is not available0x01 = The register is available and all related settings are OK0x80 = A value in the register is set out of rangeField Name: Absolute Offset Offset: 0x0001 Size: 4 Bytes Type: Read/WriteDescription: Writing a floating point value to this field directly sets the offset in DN (digital numbers). Forexample, if you set this value to +5.00, you would increase the digital values output from thecamera by 5.The allowed range for the absolute offset can vary depending on how the camera is configured.You should check the absolute min and absolute max fields of this register to determine theallowed range with the current configuration. The increment is 0.01.The value in this field is a standard IEEE-754 single precision (32 bit) floating point number.See Section 6.1 on page 159 for more information about offset.Field Name: Absolute Min Offset: 0x0005 Size: 4 Bytes Type: Read onlyDescription: Minimum allowed floating point value for the absolute offset setting.The value in this field is a standard IEEE-754 single precision (32 bit) floating point number.Field Name: Absolute Max Offset: 0x0009 Size: 4 Bytes Type: Read onlyDescription: Maximum allowed floating point value for the absolute offset setting.The value in this field is a standard IEEE-754 single precision (32 bit) floating point number.