Configuring the Camera282 Basler sprint Color Cameras7.3.1 The Binary Read/Write Command ProtocolWith the binary read/write command protocol, data is placed into a “frame” and sent to the camera.When the frame is received, it is checked for validity. If valid, the data is extracted from the frameand the command is executed.This section describes the basic layout of a binary command frame. Figure 86 shows a graphicalrepresentation of the fields within a binary command frame. The text below the graphic describeseach field of the command frame in detail.Fig. 86: Representation of a Command Frame and ResponseBFS Binary Frame Start fieldIdentifies the start of a binary frame.Size = 1 byteThe value of the BFS byte is always 0x01.FTF Frame Type and Format fieldIdentifies the frame type and format.Size = 1 byteThe bits in the FTF field are assigned as follows:The MSB of the FTF field is on the left (highest bit of the opcode) and the LSB of the fieldis on the right (lowest bit of the address length).7 6 5 4 3 2 1 0OpCode BCC-CodeAddrLen