Configuring the Camera236 Basler sprint Color CamerasFPGA Status InquiryThe camera has been programmed to detect several error conditions in its field programmable gatearray (FPGA). When an error condition is detected, a flag is set. The FPGA status inquiry registerallows you to read the error flags.Register Base Address: 0x0C10Field Name: Register Status Offset: 0x0000 Size: 1 Byte Type: Read onlyDescription: The integer value in this field indicates the status of this inquiry register:0x00 = The register is not available0x01 = The register is availableField Name: FPGA Status Offset: 0x0001 Size: 1 Byte Type: Read onlyDescription: Each bit in this field (except bit 7) specifies an error condition (see table below). Bit 0 is the leastsignificant bit. If a bit is set to 1, the error condition assigned to that bit is present. If the bit is set to0, the error is not present.Bit Description0 No FPGA firmware available.1 FPGA firmware is available, but the firmware has failed to load.2 The camera’s maximum line rate has been exceeded.(Note: If you are operating the camera in ExSync programmable mode and you triggerthe camera faster than allowed, the camera will automatically ignore any triggersignals that would cause a max line rate exceeded condition and this bit will not beset.)3 There is no ExSync signal.4 Reserved5 Reserved6 ReservedReserved7 Low line rate compensation activity (1=active, 0=inactive, see Section 4.1.3 onpage 102).