4.24.3 37-2* Center Winder37-20 Winder Mode SelectionOption: Function:[0] * Wind[1] Unwind37-21 Tension Set PointRange: Function:0 %* [0 - 100 %]37-22 Taper Set PointRange: Function:0 %* [-110 - 110 %]37-23 Partial Roll Diameter ValueRange: Function:5 %* [5 - 100 %]37-24 Core1 DiameterRange: Function:5 %* [5 - 100 %]37-25 Core2 DiameterRange: Function:5 %* [5 - 100 %]37-26 Winder Jog SpeedRange: Function:0 %* [0 - 100 %]37-27 TLD Low LimitRange: Function:0 %* [0 - 100 %]37-28 TLD High LimitRange: Function:0 %* [0 - 100 %]37-29 TLD TimerRange: Function:0.001 s* [0.001 - 5 s]37-30 TLDOnDelayOption: Function:[0] Disabled[1] * Enabled37-31 Diameter Limit DetectorRange: Function:100 %* [0 - 100 %]37-32 Initial Diameter MeasurementOption: Function:[0] * Set diameter when diameter reset[1] Set diameter based on analog signal37-33 Diameter Measurement InputOption: Function:[0] * No Function[1] Input53(0~10 VDC or 0~20 mA )[2] Input54(0~10 VDC or 0~20 mA )37-34 Reading at CoreRange: Function:0* [0 - 10 ]37-35 Reading at Full RollRange: Function:0 V* [0 - 20 V]37-36 Tension Set Point InputOption: Function:[0] * Par.3721[1] Input53(0~10 VDC or 0~20 mA )[2] Input54(0~10 VDC or 0~20 mA )37-37 Taper Set Point InputOption: Function:[0] * Par.3722[1] Input53(0~10 VDC or 0~20 mA )[2] Input54(0~10 VDC or 0~20 mA )37-38 Tension Feedback InputOption: Function:[0] * No Function[1] Input53(0~10 VDC or 0~20 mA )[2] Input54(0~10 VDC or 0~20 mA )37-39 Tension Feedback TypeOption: Function:[0] * Load cell[1] Dancer37-40 Center Winder Cmd SrcOption: Function:[0] Digital and parameter[1] * Parameter 3754~3759 control the functions[2] Digital input control37-41 Diameter Change RateRange: Function:0.001 %* [0.001 - 0.05 %]37-42 Tapered Tension Change RateRange: Function:0.1 %* [0.1 - 1 %]37-43 Diameter Calculator Min SpeedRange: Function:0 %* [0 - 100 %]Parameter Descriptions Programming Guide110 Danfoss A/S © Rev. 2014-03-31 All rights reserved. MG06C40244