5.1.6 2-** BrakesPar. No. # Parameter description Default value 2-set-up ChangeduringoperationConver-sion indexType2-0* DC-Brake2-00 DC Hold/Motor Preheat Current 50 % All set-ups TRUE 0 Uint162-01 DC Brake Current 50 % All set-ups TRUE 0 Uint162-02 DC Braking Time 10 s All set-ups TRUE -1 Uint162-04 DC Brake Cut In Speed 0 Hz All set-ups TRUE -1 Uint162-06 Parking Current 100 % All set-ups TRUE 0 Uint162-07 Parking Time 3 s All set-ups TRUE -1 Uint162-1* Brake Energy Funct.2-10 Brake Function [0] Off All set-ups FALSE - Uint82-11 Brake Resistor (ohm) ExpressionLimit All set-ups FALSE -1 Uint162-12 Brake Power Limit (kW) ExpressionLimit All set-ups TRUE 0 Uint322-14 Brake voltage reduce 0 V All set-ups FALSE 0 Uint162-16 AC Brake, Max current 100 % All set-ups TRUE -1 Uint162-17 Over-voltage Control [0] Disabled All set-ups TRUE - Uint82-19 Over-voltage Gain 100 % All set-ups TRUE 0 Uint162-2* Mechanical Brake2-20 Release Brake Current 0 A All set-ups TRUE -2 Uint322-22 Activate Brake Speed [Hz] 0 Hz All set-ups TRUE -1 Uint165.1.7 3-** Reference/RampsPar. No. # Parameter description Default value 2-set-up ChangeduringoperationConver-sion indexType3-0* Reference Limits3-00 Reference Range [0] Min - Max All set-ups TRUE - Uint83-01 Reference/Feedback Unit ExpressionLimit All set-ups TRUE - Uint83-02 Minimum Reference 0 ReferenceFeedbackUnit All set-ups TRUE -3 Int323-03 Maximum Reference ExpressionLimit All set-ups TRUE -3 Int323-04 Reference Function [0] Sum All set-ups TRUE - Uint83-1* References3-10 Preset Reference 0 % All set-ups TRUE -2 Int163-11 Jog Speed [Hz] 5 Hz All set-ups TRUE -1 Uint163-12 Catch up/slow Down Value 0 % All set-ups TRUE -2 Int163-14 Preset Relative Reference 0 % All set-ups TRUE -2 Int163-15 Reference 1 Source [1] Analog Input 53 All set-ups TRUE - Uint83-16 Reference 2 Source [2] Analog Input 54 All set-ups TRUE - Uint83-17 Reference 3 Source [11] Local bus reference All set-ups TRUE - Uint83-18 Relative Scaling Reference Resource [0] No function All set-ups TRUE - Uint83-4* Ramp 13-40 Ramp 1 Type [0] Linear All set-ups TRUE - Uint83-41 Ramp 1 Ramp Up Time ExpressionLimit All set-ups TRUE -2 Uint323-42 Ramp 1 Ramp Down Time ExpressionLimit All set-ups TRUE -2 Uint323-5* Ramp 23-50 Ramp 2 Type [0] Linear All set-ups TRUE - Uint83-51 Ramp 2 Ramp Up Time ExpressionLimit All set-ups TRUE -2 Uint323-52 Ramp 2 Ramp Down Time ExpressionLimit All set-ups TRUE -2 Uint323-6* Ramp 33-60 Ramp 3 Type [0] Linear All set-ups TRUE - Uint8Parameter Lists Programming GuideMG06C402 Danfoss A/S © Rev. 2014-03-31 All rights reserved. 1175 5